Leave Your Message

Weather-Resistant Power Cable Assemblies 600V - China Suppliers & Factory for Construction & Outdoor Lighting

,

Applications
This product is designed to provide reliable 120 volt aerial service for temporary applications at construction sites, as well as for outdoor and street lighting. It is suitable for services operating at 600 volts or lower, with a maximum conductor temperature rating of 75 degrees Celsius.

,

Construction
Our premium cables feature a concentric strand or compressed 1350-H19 conductor, insulated with high-quality polyethylene or cross-linked polyethylene. The neutral messenger is available in concentric strand AAC, ACSR, or 6201 alloy, ensuring durability and performance. As a leading factory in China, we supply high-standard products that meet rigorous industry requirements.

,
    container

    heading-type-1

    div容器

    Code Name Size
    AWG or MCM
    Aluminum Wires Steel Wires Conductor Diameter
    (mm)
    Insulation thickness
    (mm)
    Overall Diameter
    (mm)
    Rated Strength
    (LBS)
    Mass of Wire (LBS/Kft) Ampacity
    (A)
    XLPE
    Number Diameter (mm) Number Diameter (mm) XLPE Poly
    WALNUT 6 6 1.68 1 1.68 5.04 0.76 6.56 1131 49 47 105
    Butternut 4 6 2.12 1 2.12 6.36 0.76 7.88 1760 71.8 70 135
    Hickory 4 6 2.12 1 2.12 6.36 0.76 7.88 2240 81.6 79.8 135
    Pignut 2 6 2.67 1 2.67 8.01 1.14 10.29 2710 118.1 114.8 180
    Beech 2 6 2.67 1 2.67 8.01 1.14 10.29 3460 134.1 130.7 180
    Chestnut 1 6 3.00 1 3.00 9.00 1.14 11.28 3370 145.5 141.8 210
    Almond 1/0 6 3.37 1 3.37 10.11 1.52 13.15 4160 190.4 184.8 235
    Pecan 2/0 6 3.78 1 3.78 11.34 1.52 14.38 5040 234.2 227.9 270
    Filbert 3/0 6 4.25 1 4.25 12.75 1.52 15.79 6290 288.5 281.4 305
    Buckeye 4/0 6 4.77 1 4.77 14.31 1.52 17.35 7930 365.5 348.5 345
    Hackberry 266.8 18 3.09 1 3.09 15.45 1.52 18.49 6540 354.8 346.8 435
    Frequently Asked Questions
    What is the rated strength of the Buckeye conductor?
    The Buckeye conductor (size 4/0 AWG or MCM) has a rated strength of 7,930 LBS, featuring an overall diameter of 17.35 mm and an ampacity rating of 345 A under XLPE insulation.
    How do Hickory and Butternut conductors differ in specifications?
    While both Hickory and Butternut share the same size (4 AWG), conductor diameter (6.36 mm), and insulation thickness (0.76 mm), Hickory has a higher rated strength of 2,240 LBS compared to Butternut's 1,760 LBS. Hickory also has a slightly higher mass of wire (81.6 LBS/Kft for XLPE) compared to Butternut (71.8 LBS/Kft).
    Which conductor has the highest ampacity rating listed in this table?
    The Hackberry conductor has the highest ampacity rating of 435 A (XLPE). It also has the largest size at 266.8 AWG or MCM, with an overall diameter of 18.49 mm.
    What is the insulation thickness range for the listed conductors?
    The insulation thickness ranges from a minimum of 0.76 mm (for Walnut, Butternut, and Hickory) up to a maximum of 1.52 mm (for Almond, Pecan, Filbert, Buckeye, and Hackberry). Conductor sizes in between, such as Pignut, Beech, and Chestnut, have an insulation thickness of 1.14 mm.
    What is the overall diameter of the Walnut conductor?
    The Walnut conductor has an overall diameter of 6.56 mm. It is the smallest size listed (6 AWG or MCM), with a conductor diameter of 5.04 mm, a rated strength of 1,131 LBS, and an ampacity rating of 105 A under XLPE.

    Leave Your Message