Purpose and Structure of Preformed Guard Wires

Preformed guard wires (SHL) are essential components designed to protect conductors in various applications from vibrations, clamp pressure, abrasion, arcing, and other external damages. As a reliable solution from reputable China suppliers, these guard wires ensure the longevity and performance of electrical systems.

In cases of mild abrasion, our preformed guard wires effectively shield compromised conductor sections from further arcing and damage. They serve as repair strips that restore the original mechanical strength and electrical conductivity of damaged conductors.

Moreover, these guard wires protect branch clamps, preventing the adverse effects of bending and abrasion at conductor branch points. This protective mechanism is crucial for maintaining system integrity.

The structure of our preformed guard wires, manufactured in our state-of-the-art factory, is straightforward yet effective: a set of preformed wires is crafted into a hollow tube that generates a gripping force when wrapped around the conductor, ensuring robust protection.

    container

    heading-type-1

    div容器

    Selection Table of Preformed Armor Rods for Steel - Reinforced Aluminum Stranded Wire

    Company Product Model Industry Standard Model Applicable Conductor Type (GB1179 - 83)
    Steel - Reinforced Aluminum Stranded Wire LGJ/LGJF
    Reference Length
    (mm)
    Wire Diameter
    (mm)
    Wire Weight
    (Kg)
    Color Code
    Conductor Model Outer Diameter (mm)
    HL - 35/6 HL - 35/6 Jun-35 8.16 1100 3 0.22 Red
    HL - 50/8 HL - 50/8 Aug-50 9.36 1270 3 0.3 Black
    HL - 95/15 HL - 95/15 95/15 13.37 1400 3.6 0.55 Yellow
    HL - 95/20 HL - 95/20 95/20 13.57 - 0.58 Yellow - green
    HL - 95/55 HL - 95/55 95/55 16.8 1500 3.6 0.7 Red
    HL - 120/7 HL - 120/7 120/7 14.5 1400 3.6 0.58 White
    HL - 120/20 HL - 120/20 120/20 15.07 - 0.63 Blue - white
    HL - 120/25 HL - 120/25 120/25 15.74 4.6 0.63 Brown
    HL - 150/8 HL - 150/8 150/8 16 1800 3.6 0.75 Red
    HL - 150/20 HL - 150/20 150/20 16.67 1500 - 0.7 Red
    HL - 150/25 HL - 150/25 150/25 17.1 3.6 0.75 Blue
    HL - 150/35 HL - 150/35 150/35 17.9 - - Blue - green
    HL - 185/10 HL - 185/10 185/10 18.5 - 1.28 Yellow
    HL - 185/25 HL - 185/25 185/25 18.8 1800 - 1.31 White
    HL - 185/30 HL - 185/30 185/30 19.38 - 1.3 Blue - green
    HL - 185/45 HL - 185/45 185/45 19.4 4.6 - White
    HL - 210/10 HL - 210/10 210/10 19.9 - 1.3 White
    HL - 210/25 HL - 210/25 210/25 20.38 - 1.31 Brown
    HL - 210/50 HL - 210/50 210/50 20.86 - - Purple
    HL - 240/30 HL - 240/30 240/30 21.6 1900 4.6 1.53 Blue
    HL - 240/55 HL - 240/55 240/55 22.6 - - Blue - green
    HL - 300/15 HL - 300/15 300/15 23.01 2000 6.3 2.26 Black
    HL - 300/20 HL - 300/20 300/20 23.43 - 2.44 White
    HL - 300/25 HL - 300/25 300/25 23.76 - - -
    HL - 300/50 HL - 300/50 300/50 24.26 - 2.46 Brown
    HL - 300/70 HL - 300/70 300/70 25.2 - 2.48 Blue
    HL - 400/20 HL - 400/20 400/20 26.91 2200 6.3 2.98 Blue - green
    HL - 400/35 HL - 400/35 400/35 26.73 - 3 Green
    HL - 400/50 HL - 400/50 400/50 27.82 - - Yellow
    HL - 400/95 HL - 400/95 400/95 28.14 - 3.1 White
    HL - 500/35 HL - 500/35 500/35 30 2500 6.3 3.77 Brown
    HL - 500/45 HL - 500/45 500/45 30.3 - - Orange
    HL - 500/65 HL - 500/65 500/65 30.6 - - Purple
    HL - 630/45 HL - 630/45 630/45 33.4 7.8 5.1 Yellow - green
    HL - 630/80 HL - 630/80 630/80 34.32 - 5.4 Black
    HL - 630/100 HL - 630/100 630/100 35.42 - 6 Red
    HL - 800/55 HL - 800/55 800/55 38.4 7.8 6 Red
    HL - 800/70 HL - 800/70 800/70 38.58 - 6.1 Blue
    HL - 800/100 HL - 800/100 800/100 38.98 - 6.2 Blue - green

    Frequently Asked Questions (FAQ)

    Q1 What is the primary function of Preformed Armor Rods for ACSR conductors?

    Preformed armor rods are designed to protect transmission conductors against dynamic bending stresses, aeolian vibration fatigue, clamping stress, and electrical flashover/arcing at suspension points.

    Q2 How do I select the right armor rod model from the specification table?

    Identify the specific model and overall outer diameter of your steel-reinforced aluminum stranded wire (LGJ/LGJF). Match the conductor diameter with the table's "Outer Diameter" range to find the corresponding product model, reference length, and wire diameter.

    Q3 What is the purpose of the Color Code on the armor rods?

    The color code serves as a visual identification aid on-site to ensure accurate matching with specific conductor sizes and to mark the center installation position for quick and balanced fitting.

    Q4 Can preformed armor rods be reused after being removed?

    Reusing preformed armor rods is not recommended for major structural suspension points once they have experienced operational fatigue or mechanical distortion, as their gripping strength and fatigue resistance may be compromised.

    Q5 What standard do these specifications comply with?

    These models comply with standard GB1179-83 specifications for steel-reinforced aluminum stranded conductors (LGJ/LGJF) and meet general international engineering requirements for overhead power line hardware.

    Q6 Are special tools required to install preformed armor rods?

    No specialized tools are required. Preformed armor rods can be installed manually by wrapping them helically around the conductor, ensuring a uniform and secure fit along the marked center point.