+86 13777722188
0102030405
Preformed Binding Wire Series - China Suppliers and Factory for Insulator Top Binding Wire Solutions
container
heading-type-1
div容器
Selection Table for Preformed Insulator Top Binding Wires
| Company Product Model | Applicable Conductor Diameter Range (mm) | Product Parameter Description | Applicable International Conductors | |||
| Color Code | Number of Pieces per Set | L.J | Common Insulation 10KV | Thin Insulation 10KV | ||
| DB - 0600 | 4.83 – 5.46 | Blue | 2 | 16 | 10 | |
| DB - 0601 | 5.47 – 6.20 | Brown | 2 | 16 | ||
| DB - 0602 | 6.21 – 7.04 | Orange | 2 | 25 | ||
| DB - 0603 | 7.05 – 8.00 | Purple | 2 | 35 | ||
| DB - 0604 | 8.01 – 9.07 | Red | 2 | 50 | ||
| DB - 0605 | 9.08 – 10.29 | Yellow | 2 | |||
| DB - 0606 | 10.3 – 11.66 | Blue | 2 | 70 | ||
| DB - 0607 | 11.67 – 13.21 | Orange | 2 | 95 | 10, 16 | |
| DB - 0608 | 13.22 – 14.94 | Red | 2 | 120 | 25 | |
| DB - 0609 | 14.95 – 16.89 | Purple | 2 | 150 | 25, 35 | 35, 50 |
| DB - 0610 | 16.9 – 19.18 | Brown | 2 | 185, 210 | 50 | 70 |
| DB - 0611 | 19.2 – 21.79 | Red | 2 | 240 | 70, 95 | 95, 120 |
| DB - 0612 | 21.82 – 24.59 | Blue | 2 | 300 | 120, 150 | 150, 185 |
| DB - 0613 | 24.61 – 27.84 | Green | 2 | 400 | 185 | 240 |
Note: Suitable for right - hand lay bare conductors and insulated conductors.
Frequently Asked Questions (FAQ)
How do I choose the correct preformed insulator top binding wire model?
You should select the model based on your conductor's outer diameter. Match your measured diameter (in mm) with the "Applicable Conductor Diameter Range" in the selection table above to find the corresponding product model.
What is the significance of the color code on the binding wires?
The color code is used for quick identification of the product model and size during installation. This helps installers quickly verify that the correct binding wire is being used for the specific conductor size.
Can these preformed top binding wires be used for left-hand lay conductors?
No, these standard models are specifically designed and optimized for right-hand lay bare conductors and insulated conductors. Using them on left-hand lay conductors is not recommended.
How many pieces of binding wires are included in one set?
Each standard product set contains 2 pieces of preformed insulator top binding wires to ensure a secure and balanced installation on the insulator.
Are these preformed binding wires suitable for 10KV insulated conductors?
Yes, they are compatible with both common insulation 10KV and thin insulation 10KV conductors. Please refer to the specific columns in the selection table to match your conductor specifications.