Kabel ABC SANS 1418 Kabel Udara sing Nyengkuyung Mandiri
katrangan
ABC (Aerial Bundled Cable) dirancang kanggo distribusi daya overhead sing aman lan efisien, kanthi konduktor insulasi sing dibundel kanggo nyegah kontak karo elemen eksternal. Konstruksine sing awet tahan cuaca sing atos, dadi pilihan praktis kanggo subnetwork kutha lan jalur pedesaan sing terpencil sing mbutuhake keandalan jangka panjang.
APLIKASI
Tegangan sing dirating
Tegangan sing dirating saka kabel yaiku tegangan referensi sing dirancang kanggo kabel kasebut lan digunakake kanggo nemtokake tes listrik.
Tegangan sing dirating dinyatakake ing nilai gabungan U0/U (Um), kanthi unit kV.
-U0 nggambarake nilai efektif voltase antarane konduktor saka kabel sing diisolasi lan lemah
U0 = 0.6kV
-U iku nilai efektif voltase antarane rong jalur fase kabel multi-inti
U = 1.0kV
-Um nggambarake nilai efektif maksimum saka voltase jaringan paling dhuwur sing bisa digunakake piranti kasebut
-Um = 1.2kV
Ing sistem AC, voltase nominal kabel kudu paling ora padha karo voltase nominal sistem sing dirancang kanggo kabel kasebut.
Kabel saka standar iki uga bisa digunakake ing sistem DC, sing ing kasus iki voltase maksimal sing dirating menyang ground ora kena ngluwihi 0.9kV.
Kinerja
Kepatuhan Lokal: Kabel SANS 1418 ABC dirancang kanggo tundhuk karo standar nasional Afrika Selatan, njamin kompatibilitas karo peraturan lan praktik lokal. Kekokohan: Tahan radiasi UV, bahan kimia, lan keausan mekanik, njamin daya tahan lan umur dawa ing kahanan lingkungan Afrika Selatan sing tantangan. Fleksibilitas: Cocok kanggo aplikasi kutha lan pedesaan, nyedhiyakake distribusi listrik sing bisa dipercaya ing macem-macem setelan. Keamanan: Dirancang kanggo nyuda bebaya listrik lan njamin operasi sing aman miturut standar Afrika Selatan. Dampak Sosial-Ekonomi: Nggampangake upaya elektrifikasi pedesaan, nyumbang kanggo pembangunan sosio-ekonomi lan ningkatake kualitas urip ing komunitas sing kurang terlayani.
Sifat-sifat konduktor lan inti
| Jenis konduktor utawa inti | Jembar penampang nominal mm | Jumlah kabel min. | Resistensi ing 20 °C Ω/km Maks. | Diane supir. | Gaya putus (N) | Kekandelan dielektrik mm | Diameter njaba mm | |||||
| MIN | MAKSIMUM | MIN | MAKSIMUM | |||||||||
| Fase utawa netral bantu utawa non-bearing regangan (aluminium) | 16MM2 | 6 | 1.91 | 4.6 | 5.1 | 2070 | 1.2 | 7.0 | 7.8 | |||
| 25MM2 | 6 | 1.2 | 5.8 | 6.3 | 3300 | 1.4 | 8.6 | 9.4 | ||||
| 35MM2 | 6 | 0.868 | 6.8 | 7.3 | 4500 | 1.6 | 10 | 10.9 | ||||
| 50MM2 | 6 | 0.641 | 7.9 | 8.4 | 6200 | 1.6 | 11.1 | 12 | ||||
| 70MM2 | 12 | 0.443 | 9.7 | 10.2 | 8900 | 1.8 | 13.3 | 14.2 | ||||
| 95MM2 | 15 | 0.32 | 11 | 12 | 12300 | 1.8 | 14.6 | 16 | ||||
| 120MM2 | 15 | 0.253 | 12.5 | 13.5 | 15600 | 1.8 | 16.3 | 17.5 | ||||
| 150MM2 | 15 | 0.206 | 13.9 | 15 | 19200 | 1.8 | 17.1 | 18.6 | ||||
| inti lampu (aluminium) | 16MM2 | 6 | 1.91 | 4.6 | 5.1 | 2070 | 1.2 | 7.0 | 7.8 | |||
| 25MM2 | 6 | 1.2 | 5.8 | 6.3 | 3300 | 1.4 | 8.6 | 9.4 | ||||
| Pendukung (paduan aluminium) | 54.6mm2 | 7 | 7/3.15 | 9.2 | 9.6 | 16600 | 1.6 | 12.3 | 13 | |||
| 70mm2 | 7 | 7/3.5 | 10 | 10.6 | 20100 | 1.6 | 12.9 | 13.8 | ||||
Kabel Bundel Udara SANS 1418
| Spesifikasi model | Inti Fase | Inti Netral | Kabel Lengkap | |||||||||
| No. & Area Bagian | Cacahing kawat | Diane supir. | Ketebalan Isolasi | No. & Area Bagian | Cacahing kawat | Diane supir. | Ketebalan Isolasi | Diameter Sakabèhé (Kira-kira) | Bobot (Kira-kira) | |||
| MIN | MAKSIMUM | MIN | MAKSIMUM | |||||||||
| ABC 2X16 | 1X16 | 7 | 4.6 | 5.1 | 1.2 | 1X16 | 7 | 4.6 | 5.1 | 1.2 | 14.2 | 127 |
| ABC 4X16 | 3X16 | 7 | 4.6 | 5.1 | 1.2 | 1X16 | 7 | 4.6 | 5.1 | 1.2 | 17.1 | 253 |
| ABC 2X25 | 1x25 | 7 | 5.8 | 6.3 | 1.4 | 1x25 | 7 | 5.8 | 6.3 | 1.4 | 17.2 | 193 |
| ABC 4X25 | 3x25 | 7 | 5.8 | 6.3 | 1.4 | 1x25 | 7 | 5.8 | 6.3 | 1.4 | 20.8 | 387 |
| ABC 2X35 | 1x35 | 7 | 6.8 | 7.3 | 1.6 | 1x35 | 7 | 6.8 | 7.3 | 1.6 | 20.2 | 263 |
| ABC 4X35 | 3x35 | 7 | 6.8 | 7.3 | 1.6 | 1x35 | 7 | 6.8 | 7.3 | 1.6 | 24.4 | 527 |
| ABC 2X50 | 1x50 | 7 | 7.9 | 8.4 | 1.6 | 1x50 | 7 | 7.9 | 8.4 | 1.6 | 21.8 | 338 |
| Spesifikasi model | Inti Fase | Inti Netral | Kabel Lengkap | |||||||||
| No. & Area Bagian | Cacahing kawat | Diane supir. | Ketebalan Isolasi | No. & Area Bagian | Cacahing kawat | Diane supir. | Ketebalan Isolasi | Diameter Sakabèhé (Kira-kira) | Bobot (Kira-kira) | |||
| MIN | MAKSIMUM | MIN | MAKSIMUM | |||||||||
| ABC 3X25+54.6 | 3x25 | 7 | 5.8 | 6.3 | 1.4 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 23.2 | 491 | |
| ABC 3X35+54.6 | 3x35 | 7 | 6.8 | 7.3 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 26 | 596 | |
| ABC 3X50+54.6 | 3x50 | 7 | 7.9 | 8.4 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 27.7 | 708 | |
| ABC 3X70+54.6 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 31.9 | 937 | |
| ABC 3X70+70 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 32.5 | 943 | |
| ABC 3X95+54.6 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 35 | 1174 | |
| ABC 3X95+70 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 35.6 | 1214 | |
| ABC 3X120+70 | 3x120 | 19 | 12.5 | 13.5 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 37.6 | 1424 | |
| ABC 3X150+70 | 3x150 | 19 | 13.9 | 15 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 40.7 | 1679 | |
| Spesifikasi model | Inti Fase | Inti Netral | Kabel Lengkap | |||||||||
| No. & Area Bagian | Cacahing kawat | Diane supir. | Ketebalan Isolasi | No. & Area Bagian | Cacahing kawat | Diane supir. | Ketebalan Isolasi | Diameter Sakabèhé (Kira-kira) | Bobot (Kira-kira) | |||
| MIN | MAKSIMUM | MIN | MAKSIMUM | |||||||||
| ABC 3X25+54.6+kx16 | 3x25 | 7 | 5.8 | 6.3 | 1.4 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X35+54.6+kx16 | 3x35 | 7 | 6.8 | 7.3 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X50+54.6+kx16 | 3x50 | 7 | 7.9 | 8.4 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X70+54.6+kx25 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X70+70+kx25 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| ABC 3X95+54.6+kx16 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X95+70+kx16 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| ABC 3X120+70+kx16 | 3x120 | 19 | 12.5 | 13.5 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| ABC 3X150+70+kx16 | 3x150 | 19 | 13.9 | 15 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| Inti lampu: Pangguna bisa nambah siji utawa loro kabel lampu menyang struktur produk ing ndhuwur miturut kabutuhane dhewe. Spesifikasi kabel lampu yaiku 16MM2 lan 25MM2. | ||||||||||||