Working Voltage: 600/1000 volts

,

Test Voltage: 1200 volts

,

Minimum Bending Radius: 6 x Ø

,

Operation Temperature Range: -10 °C to 60 °C

,

Short-circuit Temperature: 250 °C

,

Flame Retardant: NF C 32-070 C2

,

Insulation Resistance: 20 MΩ x km

,

Discover high-quality electrical cables designed to meet your needs with our premium products from China. As a leading supplier and factory, we ensure our cables are manufactured to the highest standards, providing reliable performance under demanding conditions. Our cables operate efficiently at a working voltage of 600/1000 volts, with a robust test voltage of 1200 volts. Designed for versatility, they maintain their exceptional performance in a wide temperature range from -10 °C to 60 °C, and can withstand short-circuit temperatures up to 250 °C.

,

With an impressive minimum bending radius of 6 x Ø and flame retardant properties compliant with NF C 32-070 C2, these cables are perfect for both residential and industrial applications. Their excellent insulation resistance of 20 MΩ x km ensures optimal safety and durability. Trust our China-based factory for your electrical cable needs and experience unparalleled quality and service.

    container

    heading-type-1

    div容器

    AWG(MCM) Cross Section mm² Insulation thickness mm Minimum Sheath thickness mm Maximum Overall diameter mm Approx Cable weight kg/km
    2 1x35 0.9 1.09 13.5 190
    1 1x50 1.0 1.09 15 245
    2/0 1x70 1.1 1.09 17 325
    3/0 1x95 1.1 1.18 19 425
    4/0 1x120 1.2 1.18 21 520
    300MCM 1x150 1.4 1.26 23 630
    500MCM 1x185 1.6 1.26 25.5 780
    750MCM 1x240 1.7 1.35 28.5 990
    - 1x300 1.8 1.43 31 1210
    - 1x400 2.0 1.52 34.2 1510
    - 1x500 2.2 1.6 38 1860
    - 1x630 2.4 1.77 44 2400
    Frequently Asked Questions
    What is the cross-section equivalent for a 500MCM cable?
    According to the specification table, a 500MCM cable corresponds to a cross-section of 1x185 mm².
    How does insulation thickness scale with larger cable sizes?
    The insulation thickness increases progressively with the cable size, starting at 0.9 mm for a 1x35 mm² (2 AWG) cable and reaching up to 2.4 mm for a 1x630 mm² cable.
    What is the maximum overall diameter for a 1x240 mm² (750MCM) cable?
    The maximum overall diameter for a 1x240 mm² (750MCM) cable is 28.5 mm.
    How much does a 1x120 mm² (4/0 AWG) cable weigh per kilometer?
    A 1x120 mm² (4/0 AWG) cable has an approximate weight of 520 kg/km.
    What is the minimum sheath thickness required for a 1x500 mm² cable?
    The minimum sheath thickness required for a 1x500 mm² cable is 1.6 mm, with a maximum overall diameter of 38 mm.