+86 13777722188
0102030405
China Suppliers Factory Preformed Binding Wire Series for Insulators - Aluminum-Clad Steel Conductor Fixing Solution
container
heading-type-1
div容器
Selection Table for Preformed Insulator Top Binding Wires
| Company Product Model | Applicable Conductor Diameter Range (mm) | Product Parameter Description | Applicable International Conductors | |||
|---|---|---|---|---|---|---|
| Color Code | Number of Pieces per Set | L.J | Common Insulation 10KV | Thin Insulation 10KV | ||
| DB - 0600 | 4.83 – 5.46 | Blue | 2 | 16 | 10 | |
| DB - 0601 | 5.47 – 6.20 | Brown | 2 | 16 | ||
| DB - 0602 | 6.21 – 7.04 | Orange | 2 | 25 | ||
| DB - 0603 | 7.05 – 8.00 | Purple | 2 | 35 | ||
| DB - 0604 | 8.01 – 9.07 | Red | 2 | 50 | ||
| DB - 0605 | 9.08 – 10.29 | Yellow | 2 | |||
| DB - 0606 | 10.3 – 11.66 | Blue | 2 | 70 | ||
| DB - 0607 | 11.67 – 13.21 | Orange | 2 | 95 | 10, 16 | |
| DB - 0608 | 13.22 – 14.94 | Red | 2 | 120 | 25 | |
| DB - 0609 | 14.95 – 16.89 | Purple | 2 | 150 | 25, 35 | 35, 50 |
| DB - 0610 | 16.9 – 19.18 | Brown | 2 | 185, 210 | 50 | 70 |
| DB - 0611 | 19.2 – 21.79 | Red | 2 | 240 | 70, 95 | 95, 120 |
| DB - 0612 | 21.82 – 24.59 | Blue | 2 | 300 | 120, 150 | 150, 185 |
| DB - 0613 | 24.61 – 27.84 | Green | 2 | 400 | 185 | 240 |
Note: Suitable for right - hand lay bare conductors and insulated conductors.
Frequently Asked Questions (FAQ)
Q1.
How do I select the right Preformed Insulator Top Binding Wire model?
Selection is based primarily on the applicable conductor diameter range (mm) and the specific type of international conductor you are using, such as L.J, Common Insulation 10KV, or Thin Insulation 10KV. Refer to our selection table to match your conductor specifications.
Q2.
What is the standard lay direction for these binding wires?
These preformed insulator top binding wires are specifically designed and suitable for right-hand lay bare conductors as well as insulated conductors.
Q3.
What is the purpose of the Color Code on the product?
The color code serves as a visual identifier to help installers quickly verify that they are using the correct size of binding wire for the corresponding conductor diameter, reducing installation errors on site.
Q4.
How many pieces are included in one standard set?
Each standard product model set includes 2 pieces of preformed binding wires, which are designed to work together for a secure and complete installation.
Q5.
Can these binding wires be used with insulated conductors?
Yes, they are suitable for both bare conductors and insulated conductors (including 10KV common and thin insulation types) within the specified diameter ranges outlined in the technical table.