ABC Cable Specifications (Phase Core & Neutral Core)
| Model specification | Phase Core | Neutral Core | Complete Cable | |||||||||
| No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | Overall Diameter (Approx.) | Weight (Approx.) | |||
| MIN | MAX | MIN | MAX | |||||||||
| ABC 2X16 | 1X16 | 7 | 4.6 | 5.1 | 1.2 | 1X16 | 7 | 4.6 | 5.1 | 1.2 | 14.2 | 127 |
| ABC 4X16 | 3X16 | 7 | 4.6 | 5.1 | 1.2 | 1X16 | 7 | 4.6 | 5.1 | 1.2 | 17.1 | 253 |
| ABC 2X25 | 1x25 | 7 | 5.8 | 6.3 | 1.4 | 1x25 | 7 | 5.8 | 6.3 | 1.4 | 17.2 | 193 |
| ABC 4X25 | 3x25 | 7 | 5.8 | 6.3 | 1.4 | 1x25 | 7 | 5.8 | 6.3 | 1.4 | 20.8 | 387 |
| ABC 2X35 | 1x35 | 7 | 6.8 | 7.3 | 1.6 | 1x35 | 7 | 6.8 | 7.3 | 1.6 | 20.2 | 263 |
| ABC 4X35 | 3x35 | 7 | 6.8 | 7.3 | 1.6 | 1x35 | 7 | 6.8 | 7.3 | 1.6 | 24.4 | 527 |
| ABC 2X50 | 1x50 | 7 | 7.9 | 8.4 | 1.6 | 1x50 | 7 | 7.9 | 8.4 | 1.6 | 21.8 | 338 |
ABC Cable Specifications with AAAC Neutral Messenger
| Model specification | Phase Core | Neutral Core | Complete Cable | |||||||||
| No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | Overall Diameter (Approx.) | Weight (Approx.) | |||
| MIN | MAX | MIN | MAX | |||||||||
| ABC 3X25+54.6 | 3x25 | 7 | 5.8 | 6.3 | 1.4 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 23.2 | 491 | |
| ABC 3X35+54.6 | 3x35 | 7 | 6.8 | 7.3 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 26 | 596 | |
| ABC 3X50+54.6 | 3x50 | 7 | 7.9 | 8.4 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 27.7 | 708 | |
| ABC 3X70+54.6 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 31.9 | 937 | |
| ABC 3X70+70 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 32.5 | 943 | |
| ABC 3X95+54.6 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 35 | 1174 | |
| ABC 3X95+70 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 35.6 | 1214 | |
| ABC 3X120+70 | 3x120 | 19 | 12.5 | 13.5 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 37.6 | 1424 | |
| ABC 3X150+70 | 3x150 | 19 | 13.9 | 15 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 40.7 | 1679 | |
ABC Cable Specifications with AAAC & Street Lighting Cores
| Model specification | Phase Core | Neutral Core | Complete Cable | |||||||||
| No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | Overall Diameter (Approx.) | Weight (Approx.) | |||
| MIN | MAX | MIN | MAX | |||||||||
| ABC 3X25+54.6+kx16 | 3x25 | 7 | 5.8 | 6.3 | 1.4 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X35+54.6+kx16 | 3x35 | 7 | 6.8 | 7.3 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X50+54.6+kx16 | 3x50 | 7 | 7.9 | 8.4 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X70+54.6+kx25 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X70+70+kx25 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| ABC 3X95+54.6+kx16 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X95+70+kx16 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| ABC 3X120+70+kx16 | 3x120 | 19 | 12.5 | 13.5 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| ABC 3X150+70+kx16 | 3x150 | 19 | 13.9 | 15 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| Lighting Cores: Users can add one or two lighting wires to the above product structure according to their own needs. The specifications of the lighting wires are 16MM2 and 25MM2. | ||||||||||||
Frequently Asked Questions (FAQ)
What does "ABC Cable" stand for and where is it used?
ABC stands for Aerial Bundled Cable. It is primarily used for overhead power distribution systems. Unlike bare conductors, ABC cables are insulated, which significantly improves safety, prevents electrical faults due to contact with tree branches, and reduces power outages.
What is the role of the AAAC Neutral Messenger core?
AAAC stands for All Aluminum Alloy Conductor. In ABC cables, the AAAC neutral messenger core serves a dual purpose: it acts as the neutral return conductor and provides the high tensile strength required to support the physical weight of the entire cable bundle between utility poles.
Can street lighting wires be added to the standard ABC cable bundle?
Yes, users can customize the cable by adding one or two street lighting cores to the main assembly. According to the specification tables, standard lighting wire sizes available are 16mm² and 25mm².
What is the standard insulation thickness for these ABC cables?
The insulation thickness varies depending on the conductor cross-sectional area. Based on the specifications, it ranges from 1.2mm (for 16mm² cores) up to 1.8mm (for larger cores like 70mm² to 150mm²).
Why are the overall diameter and weight values marked as "/" for some models?
In configurations featuring additional street lighting cores (e.g., ABC 3X25+54.6+kx16), the overall diameter and weight vary depending on the exact number and specification of the lighting cores selected by the client. These parameters are calculated dynamically upon final manufacturing design.