Standard Phase & Neutral Core Specifications
| Model specification | Phase Core | Neutral Core | Complete Cable | |||||||||
| No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | Overall Diameter (Approx.) | Weight (Approx.) | |||
| MIN | MAX | MIN | MAX | |||||||||
| ABC 2X16 | 1X16 | 7 | 4.6 | 5.1 | 1.2 | 1X16 | 7 | 4.6 | 5.1 | 1.2 | 14.2 | 127 |
| ABC 4X16 | 3X16 | 7 | 4.6 | 5.1 | 1.2 | 1X16 | 7 | 4.6 | 5.1 | 1.2 | 17.1 | 253 |
| ABC 2X25 | 1x25 | 7 | 5.8 | 6.3 | 1.4 | 1x25 | 7 | 5.8 | 6.3 | 1.4 | 17.2 | 193 |
| ABC 4X25 | 3x25 | 7 | 5.8 | 6.3 | 1.4 | 1x25 | 7 | 5.8 | 6.3 | 1.4 | 20.8 | 387 |
| ABC 2X35 | 1x35 | 7 | 6.8 | 7.3 | 1.6 | 1x35 | 7 | 6.8 | 7.3 | 1.6 | 20.2 | 263 |
| ABC 4X35 | 3x35 | 7 | 6.8 | 7.3 | 1.6 | 1x35 | 7 | 6.8 | 7.3 | 1.6 | 24.4 | 527 |
| ABC 2X50 | 1x50 | 7 | 7.9 | 8.4 | 1.6 | 1x50 | 7 | 7.9 | 8.4 | 1.6 | 21.8 | 338 |
Specifications with AAAC Neutral Messenger Core
| Model specification | Phase Core | Neutral Core | Complete Cable | |||||||||
| No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | Overall Diameter (Approx.) | Weight (Approx.) | |||
| MIN | MAX | MIN | MAX | |||||||||
| ABC 3X25+54.6 | 3x25 | 7 | 5.8 | 6.3 | 1.4 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 23.2 | 491 | |
| ABC 3X35+54.6 | 3x35 | 7 | 6.8 | 7.3 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 26 | 596 | |
| ABC 3X50+54.6 | 3x50 | 7 | 7.9 | 8.4 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 27.7 | 708 | |
| ABC 3X70+54.6 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 31.9 | 937 | |
| ABC 3X70+70 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 32.5 | 943 | |
| ABC 3X95+54.6 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | 35 | 1174 | |
| ABC 3X95+70 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 35.6 | 1214 | |
| ABC 3X120+70 | 3x120 | 19 | 12.5 | 13.5 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 37.6 | 1424 | |
| ABC 3X150+70 | 3x150 | 19 | 13.9 | 15 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | 40.7 | 1679 | |
Specifications with Neutral Messenger & Optional Lighting Cores
| Model specification | Phase Core | Neutral Core | Complete Cable | |||||||||
| No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | No.& Section Area | No.of wire | Dia.of Conductor | Insulation Thickness | Overall Diameter (Approx.) | Weight (Approx.) | |||
| MIN | MAX | MIN | MAX | |||||||||
| ABC 3X25+54.6+kx16 | 3x25 | 7 | 5.8 | 6.3 | 1.4 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X35+54.6+kx16 | 3x35 | 7 | 6.8 | 7.3 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X50+54.6+kx16 | 3x50 | 7 | 7.9 | 8.4 | 1.6 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X70+54.6+kx25 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X70+70+kx25 | 3x70 | 19 | 9.7 | 10.2 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| ABC 3X95+54.6+kx16 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 54.6 | 7/3.15 | 9.45 | 1.6 | / | / | |
| ABC 3X95+70+kx16 | 3x95 | 19 | 11 | 12 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| ABC 3X120+70+kx16 | 3x120 | 19 | 12.5 | 13.5 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| ABC 3X150+70+kx16 | 3x150 | 19 | 13.9 | 15 | 1.8 | AAAC 70 | 7/3.50 | 10.5 | 1.6 | / | / | |
| lighting cores: Users can add one or two lighting wires to the above product structure according to their own needs. The specifications of the lighting wires are 16MM2 and 25MM2. | ||||||||||||
Product Customization Note: Users can add one or two lighting wires to the above product structure according to their own needs. The specifications of the lighting wires are 16MM² and 25MM².
Frequently Asked Questions (FAQ)
What are the core components of the ABC (Aerial Bundled Cable) specifications?
ABC cables typically consist of Phase Cores, a Neutral Core (which can act as a messenger wire), and optional Lighting Cores. The phase and neutral cores are designed with specific conductor diameters and insulation thicknesses to support safe overhead power distribution.
How does the conductor insulation thickness vary across different ABC models?
Insulation thickness is scaled according to the section area. For standard configurations, it ranges from 1.2 mm (for 16mm² conductors) up to 1.8 mm (for conductors sized 70mm² to 150mm²), ensuring appropriate dielectric strength and physical protection.
What is the purpose of the AAAC Neutral Core in the cable structure?
The AAAC (All Aluminum Alloy Conductor) Neutral Core serves a dual purpose: it acts as the electrical neutral return path and functions as a high-strength messenger wire to support the mechanical tension and span load of the aerial cable bundle.
Can lighting cores be integrated into all specifications of ABC cables?
Yes, users can customize their cable configurations by adding one or two lighting wires to the standard structure. The standard specifications for these integrated lighting wires are 16mm² and 25mm² to suit street lighting or auxiliary power requirements.
How do I determine the approximate weight and diameter of the complete cable?
The overall diameter and weight depend on the conductor size and configuration. For instance, a standard ABC 4X25 has an approximate diameter of 20.8 mm and weighs roughly 387 kg/km, whereas a larger ABC 3X150+70 has an overall diameter of 40.7 mm and weighs approximately 1679 kg/km.