Leave Your Message

China Suppliers ABC CABLE SANS 1418 Self-supporting Aerial Cable Manufacturer - High Quality Power Transmission Solutions

,

Standards: SANS 1418

,

CONSTRUCTION
Phase Conductor: Featuring a circular stranded, compact aluminum conductor, optimized for efficient power transmission and enhanced mechanical strength, our products are sourced from reliable China suppliers and manufactured in our state-of-the-art factory.
Neutral/Messenger Conductor: Our stranded or compacted aluminum alloy conductor (AAAC) is engineered to endure mechanical stresses while ensuring consistent electrical reliability, perfect for various applications.
Street Lighting Conductor: An optional feature providing essential functionality for street lighting solutions in both urban and rural settings, ensuring visibility and safety.
Insulation: We utilize black polyethylene (PE) or crosslinked polyethylene (XLPE) insulation that complies with SANS standards, offering excellent electrical insulation and protection against environmental influences, making it a top choice among quality-conscious customers.

,
    container

    heading-type-1

    div容器

    Model specification Phase Core Neutral Core Complete Cable
    No.& Section Area No.of wire Dia.of Conductor Insulation Thickness No.& Section Area No.of wire Dia.of Conductor Insulation Thickness Overall Diameter (Approx.) Weight (Approx.)
    MIN MAX MIN MAX
    ABC 2X16 1X16 7 4.6 5.1 1.2 1X16 7 4.6 5.1 1.2 14.2 127
    ABC 4X16 3X16 7 4.6 5.1 1.2 1X16 7 4.6 5.1 1.2 17.1 253
    ABC 2X25 1x25 7 5.8 6.3 1.4 1x25 7 5.8 6.3 1.4 17.2 193
    ABC 4X25 3x25 7 5.8 6.3 1.4 1x25 7 5.8 6.3 1.4 20.8 387
    ABC 2X35 1x35 7 6.8 7.3 1.6 1x35 7 6.8 7.3 1.6 20.2 263
    ABC 4X35 3x35 7 6.8 7.3 1.6 1x35 7 6.8 7.3 1.6 24.4 527
    ABC 2X50 1x50 7 7.9 8.4 1.6 1x50 7 7.9 8.4 1.6 21.8 338
    Model specification Phase Core Neutral Core Complete Cable
    No.& Section Area No.of wire Dia.of Conductor Insulation Thickness No.& Section Area No.of wire Dia.of Conductor Insulation Thickness Overall Diameter (Approx.) Weight (Approx.)
    MIN MAX MIN MAX
    ABC 3X25+54.6 3x25 7 5.8 6.3 1.4 AAAC 54.6 7/3.15 9.45 1.6 23.2 491
    ABC 3X35+54.6 3x35 7 6.8 7.3 1.6 AAAC 54.6 7/3.15 9.45 1.6 26 596
    ABC 3X50+54.6 3x50 7 7.9 8.4 1.6 AAAC 54.6 7/3.15 9.45 1.6 27.7 708
    ABC 3X70+54.6 3x70 19 9.7 10.2 1.8 AAAC 54.6 7/3.15 9.45 1.6 31.9 937
    ABC 3X70+70 3x70 19 9.7 10.2 1.8 AAAC 70 7/3.50 10.5 1.6 32.5 943
    ABC 3X95+54.6 3x95 19 11 12 1.8 AAAC 54.6 7/3.15 9.45 1.6 35 1174
    ABC 3X95+70 3x95 19 11 12 1.8 AAAC 70 7/3.50 10.5 1.6 35.6 1214
    ABC 3X120+70 3x120 19 12.5 13.5 1.8 AAAC 70 7/3.50 10.5 1.6 37.6 1424
    ABC 3X150+70 3x150 19 13.9 15 1.8 AAAC 70 7/3.50 10.5 1.6 40.7 1679
    Model specification Phase Core Neutral Core Complete Cable
    No.& Section Area No.of wire Dia.of Conductor Insulation Thickness No.& Section Area No.of wire Dia.of Conductor Insulation Thickness Overall Diameter (Approx.) Weight (Approx.)
    MIN MAX MIN MAX
    ABC 3X25+54.6+kx16 3x25 7 5.8 6.3 1.4 AAAC 54.6 7/3.15 9.45 1.6 / /
    ABC 3X35+54.6+kx16 3x35 7 6.8 7.3 1.6 AAAC 54.6 7/3.15 9.45 1.6 / /
    ABC 3X50+54.6+kx16 3x50 7 7.9 8.4 1.6 AAAC 54.6 7/3.15 9.45 1.6 / /
    ABC 3X70+54.6+kx25 3x70 19 9.7 10.2 1.8 AAAC 54.6 7/3.15 9.45 1.6 / /
    ABC 3X70+70+kx25 3x70 19 9.7 10.2 1.8 AAAC 70 7/3.50 10.5 1.6 / /
    ABC 3X95+54.6+kx16 3x95 19 11 12 1.8 AAAC 54.6 7/3.15 9.45 1.6 / /
    ABC 3X95+70+kx16 3x95 19 11 12 1.8 AAAC 70 7/3.50 10.5 1.6 / /
    ABC 3X120+70+kx16 3x120 19 12.5 13.5 1.8 AAAC 70 7/3.50 10.5 1.6 / /
    ABC 3X150+70+kx16 3x150 19 13.9 15 1.8 AAAC 70 7/3.50 10.5 1.6 / /

    Lighting Cores Note: Users can add one or two lighting wires to the above product structure according to their own needs. The specifications of the lighting wires are 16MM² and 25MM².

    Frequently Asked Questions
    What are the available conductor sizes for the ABC phase cores?
    According to the specifications, the phase core sizes range from 16mm² up to 150mm² (such as 3x25, 3x70, 3x120, and 3x150) depending on the selected model.
    Can street lighting wires be added to the ABC cable structure?
    Yes, users can add one or two lighting wires to the standard product structure according to specific installation needs. The standard specifications for these lighting wires are 16mm² and 25mm².
    What type of material is used for the neutral core in these cables?
    The neutral core options include standard copper/aluminum cores or AAAC (All Aluminum Alloy Conductor) specifications like AAAC 54.6 and AAAC 70, which provide supporting strength to the cable bundle.
    What is the typical insulation thickness of these cables?
    The insulation thickness varies depending on the core cross-section area, ranging from 1.2mm for smaller cores (16mm²) up to 1.8mm for larger cores (70mm² to 150mm²).
    How does the cable weight scale with the model specifications?
    The approximate weight scales with the core size and configuration. For example, a basic ABC 2X16 cable weighs approximately 127 kg/km, while a larger ABC 3X150+70 configuration weighs approximately 1679 kg/km.