| Aluminum Conductor Steel Reinforced (ACSR) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Code Name | Product structure | Sectional Area | Diameter of Conductor | Nominal Breaking Load | Linear Mass | Maximum Resistance at 20℃ | |||||
| Aluminium Wire Diameter & Stranding | Galvanized steel Wire Diameter & Stranding | Aluminium | Galvanized steel | Aluminium & Galvanized steel | |||||||
| mm | No. | mm | No. | mm² | mm² | Total | mm | kN | kg/km | Ω/km | |
| 16 | 1.84 | 6 | 1.84 | 1 | 16.0 | 2.7 | 18.6 | 5.52 | 6.08 | 64.6 | 1.7934 |
| 25 | 2.3 | 6 | 2.3 | 1 | 24.9 | 4.2 | 29.1 | 6.91 | 9.13 | 100.9 | 1.1478 |
| 40 | 2.91 | 6 | 2.91 | 1 | 39.9 | 6.7 | 46.6 | 8.74 | 14.4 | 161.5 | 0.7174 |
| 63 | 3.66 | 6 | 3.66 | 1 | 63.1 | 10.5 | 73.6 | 11 | 21.63 | 254.4 | 0.4555 |
| 100 | 4.61 | 6 | 4.61 | 1 | 100.1 | 16.7 | 116.8 | 13.8 | 34.33 | 403.8 | 0.2869 |
| 125 | 2.97 | 18 | 2.97 | 1 | 124.7 | 6.9 | 131.6 | 14.9 | 29.17 | 397.9 | 0.2304 |
| 125 | 2.47 | 26 | 1.92 | 7 | 124.6 | 20.3 | 144.8 | 15.7 | 45.69 | 503.9 | 0.2310 |
| 160 | 3.36 | 18 | 3.36 | 1 | 159.6 | 8.9 | 168.5 | 16.8 | 36.18 | 509.3 | 0.1800 |
| 160 | 2.80 | 26 | 2.18 | 7 | 160.1 | 26.1 | 186.2 | 17.7 | 57.69 | 644.9 | 0.1805 |
| 200 | 3.76 | 18 | 3.76 | 1 | 199.9 | 11.1 | 211.0 | 18.8 | 42.22 | 636.7 | 0.1440 |
| 200 | 3.13 | 26 | 2.43 | 7 | 200.1 | 32.5 | 232.5 | 19.8 | 70.13 | 806.2 | 0.1444 |
| 250 | 3.80 | 22 | 2.11 | 7 | 249.5 | 24.5 | 274.0 | 21.6 | 68.72 | 880.6 | 0.1154 |
| 250 | 3.50 | 26 | 2.72 | 7 | 250.1 | 40.7 | 290.8 | 22.2 | 87.67 | 1007.7 | 0.1155 |
| 315 | 2.99 | 45 | 1.99 | 7 | 316.0 | 21.8 | 337.7 | 23.9 | 79.03 | 1039.6 | 0.0917 |
| 315 | 3.93 | 26 | 3.05 | 7 | 315.4 | 51.1 | 366.5 | 24.9 | 106.83 | 1269.7 | 0.0917 |
| 400 | 3.36 | 45 | 2.24 | 7 | 399.0 | 27.6 | 426.6 | 26.9 | 98.36 | 1320.1 | 0.0722 |
| 400 | 3.07 | 54 | 3.07 | 7 | 399.7 | 51.8 | 451.5 | 27.6 | 123.04 | 1510.3 | 0.0723 |
| 450 | 3.57 | 45 | 2.38 | 7 | 450.4 | 31.1 | 481.6 | 28.5 | 107.47 | 1485.2 | 0.0642 |
| 450 | 3.26 | 54 | 3.26 | 7 | 450.7 | 58.4 | 509.2 | 29.3 | 138.42 | 1699.1 | 0.0643 |
| 500 | 3.76 | 45 | 2.51 | 7 | 499.7 | 34.6 | 534.3 | 30.1 | 119.41 | 1650.2 | 0.0578 |
| 500 | 3.43 | 54 | 3.43 | 7 | 499.0 | 64.7 | 563.6 | 30.9 | 153.80 | 1887.9 | 0.0578 |
| 560 | 3.98 | 45 | 2.65 | 7 | 559.8 | 38.6 | 598.5 | 31.8 | 133.74 | 1848.2 | 0.0516 |
| 560 | 3.63 | 54 | 2.18 | 19 | 558.9 | 70.9 | 629.8 | 32.7 | 172.59 | 2103.4 | 0.0516 |
| 630 | 4.22 | 45 | 2.81 | 7 | 629.4 | 43.4 | 672.8 | 33.8 | 150.45 | 2079.2 | 0.0459 |
| 630 | 3.85 | 54 | 2.31 | 19 | 628.6 | 79.6 | 708.3 | 34.7 | 191.77 | 2366.3 | 0.0459 |
| 710 | 4.48 | 45 | 2.99 | 7 | 709.3 | 49.2 | 758.5 | 35.9 | 169.56 | 2343.2 | 0.0407 |
| 710 | 4.09 | 54 | 2.45 | 19 | 709.5 | 89.6 | 799.0 | 36.8 | 216.12 | 2666.8 | 0.0407 |
| 800 | 3.76 | 72 | 2.51 | 7 | 799.5 | 34.6 | 834.1 | 37.6 | 167.41 | 2480.2 | 0.0361 |
| 800 | 3.48 | 84 | 3.48 | 7 | 799.0 | 66.6 | 865.5 | 38.3 | 205.33 | 2732.7 | 0.0362 |
| 800 | 4.34 | 54 | 2.61 | 19 | 798.8 | 101.7 | 900.5 | 39.1 | 243.52 | 3004.9 | 0.0362 |
| 900 | 3.99 | 72 | 2.66 | 7 | 900.3 | 38.9 | 939.2 | 39.9 | 188.33 | 2790.2 | 0.0321 |
| 900 | 3.69 | 84 | 3.69 | 7 | 898.3 | 74.9 | 973.2 | 40.6 | 226.50 | 3074.2 | 0.0322 |
| 1000 | 4.21 | 72 | 2.80 | 7 | 1002.3 | 43.1 | 1045.4 | 42.1 | 209.26 | 3100.3 | 0.0289 |
| 1120 | 4.45 | 72 | 1.78 | 19 | 1119.8 | 47.3 | 1167.1 | 44.5 | 234.53 | 3464.9 | 0.0258 |
| 1120 | 4.12 | 84 | 2.47 | 19 | 1119.9 | 91.0 | 1210.9 | 45.3 | 283.17 | 3811.5 | 0.0258 |
| 1250 | 4.35 | 84 | 2.61 | 19 | 1248.4 | 101.7 | 1350.0 | 47.9 | 316.04 | 4253.9 | 0.0232 |
| 1250 | 4.70 | 72 | 1.88 | 19 | 1249.2 | 52.7 | 1301.9 | 47 | 261.75 | 3867.1 | 0.0231 |
Note: The outermost layer is twisted to the right (Z).
Frequently Asked Questions (FAQ)
Q: What does ACSR stand for and what is its main structure?
ACSR stands for Aluminum Conductor Steel Reinforced. It consists of a solid or stranded steel core surrounded by concentric layers of aluminum wires, combining the electrical conductivity of aluminum with the high mechanical strength of steel.
Q: Why is the outermost layer of ACSR twisted to the right (Z-lay)?
A right-hand lay (Z-lay) is the industry standard for the outer layer of ACSR conductors. This structural configuration ensures optimal mechanical stability, prevents unraveling during installation, and matches standard utility line hardware fittings.
Q: How does the steel core affect the performance of the conductor?
The galvanized steel core provides the primary tensile strength for the conductor. This allows for significantly higher mechanical tension, reducing physical sag across long spans and allowing for longer distances between transmission towers.
Q: At what temperature is the maximum resistance of ACSR measured?
According to international standards, the maximum DC electrical resistance of the conductor is measured and specified at a baseline temperature of 20°C to ensure consistency and performance accuracy.
Q: Can ACSR conductors be used for both transmission and distribution?
Yes, ACSR is highly versatile and widely used for both high-voltage overhead transmission lines and medium/low-voltage overhead distribution lines due to its excellent balance of cost, strength, and current capacity.