China ACSR Steel Core Aluminum Alloy Conductor - Reliable Power Transmission | Suppliers & Factory Direct
heading-type-1
Technical Specifications & Parameters
| Nominal Area | Sectional Area | Wire Diameter & Stranding | Diameter of Conductor | Linear Mass | Rated Strength | Max. D.C. Resistance at 20℃ | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Aluminum alloy | Steel | Total | Aluminum alloy | Steel | |||||||
| mm² | mm² | mm² | mm² | mm | No | mm | No | mm | kg/km | kN | Ω/km |
| 26 | 18.4 | 3.07 | 21.5 | 1.98 | 6 | 1.98 | 1 | 5.93 | 74.8 | 9.02 | 1.7934 |
| 25 | 28.8 | 4.80 | 33.6 | 2.47 | 6 | 2.47 | 1 | 7.41 | 116.3 | 13.96 | 1.1478 |
| 40 | 46.0 | 7.67 | 53.7 | 3.13 | 6 | 3.13 | 1 | 9.38 | 186.8 | 22.02 | 0.7174 |
| 63 | 72.5 | 12.1 | 84.6 | 3.92 | 6 | 3.92 | 1 | 11.8 | 293.0 | 34.68 | 0.4555 |
| 100 | 115 | 6.39 | 121 | 2.85 | 18 | 2.85 | 1 | 14.3 | 366.0 | 41.24 | 0.2880 |
| 125 | 144 | 7.99 | 152 | 3.19 | 18 | 3.19 | 1 | 16.0 | 458.6 | 51.23 | 0.2304 |
| 125 | 144 | 23.4 | 167 | 2.65 | 26 | 2.06 | 7 | 16.8 | 579.4 | 69.86 | 0.2310 |
| 160 | 184 | 10.2 | 194 | 3.61 | 18 | 3.61 | 1 | 18.0 | 587.3 | 65.58 | 0.1800 |
| 160 | 184 | 30.0 | 214 | 3.00 | 26 | 2.34 | 7 | 19.0 | 743.0 | 88.52 | 0.1805 |
| 200 | 230 | 12.8 | 243 | 4.04 | 18 | 4.04 | 1 | 20.2 | 735.6 | 81.97 | 0.1440 |
| 200 | 230 | 37.5 | 268 | 3.36 | 26 | 2.61 | 7 | 21.3 | 931.0 | 110.64 | 0.1444 |
| 250 | 288 | 28.3 | 316 | 4.08 | 22 | 2.27 | 7 | 23.1 | 1016.6 | 117.09 | 0.1154 |
| 250 | 288 | 46.9 | 335 | 3.75 | 26 | 2.92 | 7 | 23.8 | 1161.5 | 138.31 | 0.1155 |
| 315 | 383 | 25.1 | 408 | 3.20 | 45 | 2.14 | 7 | 25.8 | 1198.0 | 136.28 | 0.0917 |
| 315 | 383 | 59.0 | 442 | 4.21 | 26 | 3.28 | 7 | 26.7 | 1464.4 | 171.90 | 0.0917 |
| 400 | 460 | 31.8 | 492 | 3.61 | 45 | 2.41 | 7 | 28.9 | 1523.8 | 172.10 | 0.0722 |
| 400 | 460 | 59.7 | 520 | 3.29 | 54 | 3.29 | 7 | 29.7 | 1736.9 | 201.46 | 0.0723 |
| 450 | 518 | 35.8 | 554 | 3.83 | 45 | 2.55 | 7 | 30.6 | 1713.7 | 193.61 | 0.0642 |
| 450 | 518 | 67.1 | 585 | 3.49 | 54 | 3.49 | 7 | 31.5 | 1954.5 | 226.64 | 0.0643 |
| 500 | 575 | 39.8 | 615 | 4.04 | 45 | 2.69 | 7 | 32.3 | 1906.8 | 215.12 | 0.0578 |
| 500 | 575 | 74.6 | 650 | 3.68 | 54 | 3.68 | 7 | 33.2 | 2173.1 | 251.82 | 0.0578 |
| 560 | 645 | 44.6 | 689 | 4.27 | 45 | 2.85 | 7 | 34.2 | 2131.8 | 240.93 | 0.0516 |
| 560 | 645 | 81.6 | 726 | 3.90 | 54 | 2.34 | 19 | 35.1 | 2425.7 | 283.21 | 0.0516 |
| 630 | 725 | 31.3 | 756 | 3.58 | 72 | 2.39 | 7 | 35.8 | 2250.4 | 249.62 | 0.0459 |
| 630 | 725 | 91.8 | 817 | 4.13 | 54 | 2.48 | 19 | 37.2 | 2721.4 | 318.61 | 0.0459 |
| 710 | 817 | 35.3 | 852 | 3.80 | 72 | 2.53 | 7 | 38.0 | 2534.0 | 281.32 | 0.0407 |
| 710 | 817 | 104 | 921 | 4.39 | 54 | 2.63 | 19 | 39.5 | 3071.0 | 359.98 | 0.0407 |
| 800 | 921 | 39.8 | 961 | 4.04 | 72 | 2.69 | 7 | 40.4 | 2864.2 | 316.98 | 0.0361 |
| 800 | 921 | 76.7 | 997 | 3.74 | 84 | 3.74 | 7 | 41.1 | 3156.3 | 356.03 | 0.0362 |
| 900 | 1036 | 44.8 | 1081 | 4.28 | 72 | 2.85 | 7 | 42.8 | 3214.7 | 356.6 | 0.0321 |
| 900 | 1036 | 86.3 | 1122 | 3.96 | 84 | 3.96 | 7 | 43.6 | 3538.6 | 400.53 | 0.0322 |
| 1000 | 1151 | 93.7 | 1245 | 4.18 | 84 | 2.51 | 19 | 45.9 | 3926.6 | 446.37 | 0.0289 |
| 1120 | 1289 | 105 | 1394 | 4.42 | 84 | 2.65 | 19 | 48.6 | 4387.8 | 499.93 | 0.0258 |
Frequently Asked Questions
Q1: What is the range of Nominal Area covered in this specification?
The nominal area of the conductors ranges from a minimum of 26 mm² to a maximum of 1120 mm², offering options for various transmission line capacities.
Q2: How does the conductor diameter scale with the nominal area?
The overall diameter of the conductor scales proportionally with the nominal area, starting from 5.93 mm for the 26 mm² nominal area up to 48.6 mm for the 1120 mm² nominal area.
Q3: What is the relationship between conductor size and Maximum D.C. Resistance at 20℃?
As the nominal area increases, the Maximum D.C. Resistance decreases significantly. For instance, the 26 mm² conductor has a resistance of 1.7934 Ω/km, whereas the 1120 mm² conductor has a resistance of only 0.0258 Ω/km.
Q4: What are the stranding configurations for the steel core?
Depending on the conductor size and strength requirements, the steel core stranding consists of either 1 wire (for smaller sizes like 26 mm² to 200 mm²), 7 wires (for medium to large sizes), or 19 wires (for heavy-duty configurations like 560 mm² to 1120 mm²).
Q5: What is the rated strength of the 1120 mm² nominal area conductor?
The largest conductor listed in the specifications (1120 mm² nominal area, with a total sectional area of 1394 mm²) features a rated strength of 499.93 kN.
Q6: Why are there two listings for certain nominal areas like 125 mm², 160 mm², and 200 mm²?
These sizes offer different steel core configurations (e.g., 1 steel wire vs. 7 steel wires). This allows engineers to select either a lighter conductor or a stronger conductor with higher rated strength depending on the span and tension requirements of the transmission line.