Execution Standard: EN 50182 (Old Standard: DIN 48204)

,

Material: ACSR features galvanized steel wire and AL1 aluminum.

,

Introducing our high-performing ACSR conductor, engineered at our China factory. This superior bare conductor combines a robust steel core for enhanced mechanical strength with high-quality aluminum wires to increase current-carrying capacity. Designed for optimal performance, it offers exceptional resistance to environmental stress, ensuring safe and efficient high-voltage power delivery. As a leading supplier in the industry, we guarantee reliability and quality in every product, making us your top choice for ACSR conductors.

,
    container

    heading-type-1

    div容器

    Aluminum Conductor Steel Reinforced (ACSR)
    Code Name Old Code Name Sectional Area Product structure Diameter of Conductor Nominal Breaking Load Linear Mass Maximum Resistance at 20℃ Modulus of elasticity Coefficient of linear expansion Current-carrying capacity
    Aluminium Galvanized steel Aluminium & Galvanized steel Aluminium Wire Diameter & Stranding Galvanized steel Wire Diameter & Stranding
    mm² mm² Total mm No. mm No. mm kN kg/km Ω/km N/MM2 1/K A
    15-AL 1/3-ST1A 16/2.5 15.3 2.5 17.8 1.8 6 1.8 1 5.40 5.8 61.6 1.8769 81000 1.92x10-5 105
    24-AL 1/4-ST1A 25/4 23.9 4.0 27.8 2.25 6 2.25 1 6.75 8.95 96.3 1.2012 81000 1.92x10-5 140
    34-AL 1/6-ST1A 35/6 34.4 5.7 40.1 2.7 6 2.7 1 8.10 12.37 138.7 08342 81000 1.92x10-5 170
    44-AL 1/32-ST1A 44/32 44.0 31.7 75.6 2 14 2.4 7 11.20 44.24 369.3 0.6574 110000 1.50x10-5 170
    48-AL 1/8-ST1A 50/8 48.3 8.0 56.3 3.20 6 3.2 1 9.60 16.81 194.8 0.5939 81000 1.92x10-5 210
    51-AL 1/30-ST1A 50/30 51.2 29.8 81.0 2.33 12 2.33 7 11.70 42.98 374.7 0.5644 107000 1.53x10-5 210
    70-AL 1/11-ST1A 70/12 69.9 11.4 81.3 1.85 26 1.44 7 11.70 26.27 282.2 0.4132 77000 1.89x10-5 290
    94-AL 1/15-ST1A 95/15 94.4 15.3 109.7 2.15 26 1.67 7 13.60 34.93 380.6 0.3060 77000 1.89x10-5 350
    97-AL 1/56-ST1A 95/55 96.5 56.3 152.8 3.2 12 3.2 7 16.00 77.85 706.8 0.2992 107000 1.53x10-5 350
    106-AL1/76-ST1A 105/75 105.7 75.5 181.2 3.1 14 2.25 19 17.50 105.82 885.3 0.2742 110000 1.50x10-5 350
    122-AL /20-ST1A 120/20 121.6 19.8 141.4 2.44 26 1.9 7 15.50 44.5 491.0 0.2376 77000 1.89x10-5 410
    122-AL 1/71-ST1A 120/70 122.1 71.3 193.4 3.6 12 3.6 7 18.00 97.92 894.5 0.2364 107000 1.53x10-5 410
    128-AL 1/30-ST1A 125/30 127.9 29.8 157.8 2.33 30 2.33 7 16.30 56.41 587.0 0.2260 82000 1.78x10-5 425
    149-AL 1/24-ST1A 150/25 148.9 24.2 173.1 2.70 26 2.10 7 17.10 53.67 600.8 0.1940 77000 1.89x10-5 470
    172-AL 1/40-ST1A 170/40 171.8 40.1 211.8 2.7 30 2.7 7 18.90 74.89 788.2 0.1683 82000 1.78x10-5 520
    184-AL 1/30-ST1A 185/30 212.1 29.8 241.9 3 30 2.33 7 19.00 65.27 741.0 0.1571 77000 1.89x10-5 535
    209-AL 1/34-ST1A 210/35 209.1 34.1 243.2 3.2 26 2.49 7 20.30 73.36 844.1 0.1381 77000 1.89x10-5 590
    212-AL 1/49-ST1A 210/50 212.1 49.5 261.5 3 30 3 7 21.00 92.46 973.1 0.1363 82000 1.78x10-5 610
    231-AL 1/30-ST1A 230/30 230.9 29.8 260.8 3.5 24 2.33 7 21.00 72.13 870.9 0.1250 74000 1.96x10-5 630
    243-AL 1/39-ST1A 240/40 243.1 39.5 282.5 3.45 26 2.68 7 21.80 85.12 980.1 0.1188 77000 1.89x10-5 645
    264-AL 1/34-ST1A 265/35 263.7 34.1 297.7 3.74 24 2.49 7 22.40 81.04 994.4 0.1095 74000 1.96x10-5 680
    304-AL 1/49-ST1A 300/50 304.3 49.5 353.7 3.86 26 3 7 24.40 105.09 1227.3 0.0949 77000 1.89x10-5 740
    305-AL 1/39-ST1A 305/40 304.6 39.5 344.1 2.68 54 2.68 7 24.10 96.8 1151.2 0.0949 70000 1.93x10-5 740
    339-AL 1/30-ST1A 340/30 339.3 29.8 369.1 3.00 48 2.33 7 25.00 91.71 1171.2 0.0852 62000 2.05x10-5 790
    382-AL 1/49-ST1A 380/50 381.7 49.5 431.2 3.00 54 3 7 27.00 121.3 1442.5 0.0758 70000 1.93x10-5 840
    386-AL 1/34-ST1A 385/35 386.0 34.1 420.1 3.2 48 2.49 7 26.70 102.56 1333.6 0.0749 62000 2.05x10-5 850
    434-AL 1/56-ST1A 435/55 434.3 56.3 490.6 3.2 54 3.2 7 28.80 133.59 1641.3 0.0666 70000 1.93x10-5 900
    449-AL 1/39-ST1A 450/40 448.7 39.5 488.2 3.45 48 2.68 7 28.70 119.05 1549.1 0.0644 62000 2.05x10-5 920
    490-AL 1/64-ST1A 490/65 490.3 63.6 553.8 3.4 54 3.4 7 30.60 150.81 1852.9 0.0590 70000 1.93x10-5 960
    494-AL 1/34-ST1A 495/35 494.4 34.1 528.5 3.74 45 2.49 7 29.90 117.96 1632.6 0.0584 61000 2.09x10-5 985
    511-AL 1/45-ST1A 510/45 510.5 45.3 555.8 3.68 48 2.87 7 30.70 133.31 1765.3 0.0566 62000 2.05x10-5 995
    550-AL 1/71-ST1A 550/70 549.7 71.3 620.9 3.6 54 3.6 7 32.40 166.32 2077.2 0.0526 70000 1.93x10-5 1020
    562-AL 1/49-ST1A 560/50 561.7 49.5 611.2 3.86 48 3 7 32.20 146.28 1939.5 0.0515 62000 2.05x10-5 1040
    571-AL 1/39-ST1A 570/40 571.2 39.5 610.6 4.02 45 2.68 7 32.20 136.4 1887.1 0.0506 61000 2.09x10-5 1050
    653-AL 1/45-ST1A 650/45 653.5 45.3 698.8 4.3 45 2.87 7 34.40 156.18 2159.9 0.0442 61000 2.09x10-5 1120
    679-AL 1/86-ST1A 680/85 678.6 86.0 764.5 4 54 2.4 19 36.00 206.56 2549.7 0.0426 68000 1.94x10-5 1150
    1046-AL1/45-ST1A 1045/45 1045.6 45.3 1090.9 4.3 72 2.87 7 43 218.92 3248.2 0.0277 60000 2.17x10-5 1580
    Note: The outermost layer is twisted to the right (Z).
    Frequently Asked Questions (FAQ)

    Q1: What is ACSR conductor and how is it constructed?

    ACSR (Aluminum Conductor Steel Reinforced) consists of a solid or stranded steel core surrounded by outer strands of high-purity aluminum. This design balances the high electrical conductivity of aluminum with the superior mechanical strength of steel.

    Q2: What are the primary applications of ACSR?

    ACSR is widely used in overhead electric power transmission and distribution lines. Its high strength-to-weight ratio makes it ideal for long spans, river crossings, and installations requiring high mechanical tension.

    Q3: Why is the outermost layer of ACSR twisted to the right (Z-lay)?

    The right-hand lay (Z-lay) is the standard direction of rotation for the outer layer of ACSR. This configuration ensures structural stability during installation, prevents bird-caging under tension, and matches standard line accessories.

    Q4: How does temperature affect the maximum resistance of ACSR?

    The electrical resistance of the aluminum strands increases as temperature rises. Standard specifications list the maximum DC resistance at 20°C as a baseline for calculating line losses and efficiency during operation.

    Q5: What is the significance of the modulus of elasticity in ACSR?

    The modulus of elasticity indicates the stiffness of the conductor. It is a critical factor for engineers to calculate the sag and tension properties of the line under varying environmental loads like wind and ice.