+86 13777722188
0102030405
China AAC ASTM B231 All Aluminum Conductor Manufacturers, Suppliers & Factory for Efficient Power Transmission
container
heading-type-1
div容器
Swipe horizontally to view full table
| Code Word | Conductor Size | Stranding | Sectional Area | Diameter of Conductor | Linear Mass | Rated Strength | Max.D.C. Resistance at 20℃ | |
|---|---|---|---|---|---|---|---|---|
| cmil (AWG) | mm | No. | mm² | mm | kg/km | kN | Ohms/km | |
| Peachbell | 6 | 1.56 | 7 | 13.4 | 4.68 | 37 | 2.5 | 2.1548 |
| Rose | 4 | 1.96 | 7 | 21.1 | 5.88 | 58 | 3.9 | 1.3650 |
| Iris | 2 | 2.47 | 7 | 33.5 | 7.41 | 92 | 6.0 | 0.8595 |
| Pansy | 1 | 2.78 | 7 | 42.5 | 8.34 | 116 | 7.3 | 0.6785 |
| Poppy | 1/0 | 3.12 | 7 | 53.5 | 9.36 | 147 | 8.8 | 0.5387 |
| Aster | 2/0 | 3.50 | 7 | 67.3 | 10.5 | 184 | 11.1 | 0.4281 |
| Phlox | 3/0 | 3.93 | 7 | 84.9 | 11.79 | 233 | 13.5 | 0.3395 |
| Oxlip | 4/0 | 4.42 | 7 | 107.4 | 13.26 | 294 | 17.0 | 0.2684 |
| Valerian | 250 000 | 2.91 | 19 | 126.4 | 14.55 | 348 | 20.7 | 0.2281 |
| Sneezewort | 250 000 | 4.80 | 7 | 126.7 | 14.4 | 347 | 20.1 | 0.2276 |
| Laurel | 266 800 | 3.01 | 19 | 135.2 | 15.05 | 372 | 22.1 | 0.2132 |
| Daisy | 266 800 | 4.96 | 7 | 135.3 | 14.88 | 370 | 21.4 | 0.2132 |
| Peony | 300 000 | 3.19 | 19 | 151.9 | 15.95 | 418 | 24.3 | 0.1899 |
| Tulip | 336 400 | 3.38 | 19 | 170.5 | 16.9 | 469 | 27.3 | 0.1691 |
| Daffodil | 350 000 | 3.45 | 19 | 177.6 | 17.25 | 489 | 28.4 | 0.1623 |
| Canna | 397 500 | 3.67 | 19 | 201.0 | 18.35 | 553 | 31.6 | 0.1434 |
| Goldentuft | 450 000 | 3.91 | 19 | 228.1 | 19.55 | 628 | 35.0 | 0.1264 |
| Syringa | 477 000 | 2.88 | 37 | 241.0 | 20.16 | 665 | 38.6 | 0.1196 |
| Cosmos | 477 000 | 4.02 | 19 | 241.2 | 20.1 | 664 | 37.0 | 0.1195 |
| Hyacinth | 500 000 | 2.95 | 37 | 252.9 | 20.65 | 698 | 40.5 | 0.1140 |
| Zinnia | 500 000 | 4.12 | 19 | 253.3 | 20.6 | 697 | 38.9 | 0.1138 |
| Mistletoe | 556 500 | 3.12 | 37 | 282.9 | 21.84 | 780 | 44.3 | 0.1019 |
| Dahlia | 556 500 | 4.35 | 19 | 282.4 | 21.75 | 777 | 43.3 | 0.1021 |
| Meadowsweet | 600 000 | 3.23 | 37 | 303.2 | 22.6 | 836 | 47.5 | 0.0951 |
| Orchid | 636 000 | 3.33 | 37 | 322.2 | 23.31 | 889 | 50.4 | 0.0895 |
| Heuchera | 650 000 | 3.37 | 37 | 330.0 | 23.59 | 910 | 51.7 | 0.0874 |
| Flag | 700 000 | 2.72 | 61 | 354.5 | 24.48 | 979 | 57.1 | 0.0813 |
| Verbena | 700 000 | 3.49 | 37 | 354.0 | 24.43 | 976 | 55.4 | 0.0815 |
| Nasturtium | 715 500 | 2.75 | 61 | 362.3 | 24.75 | 1001 | 58.4 | 0.0796 |
| Violet | 715 500 | 3.53 | 37 | 362.1 | 24.71 | 999 | 56.7 | 0.0796 |
| Cattail | 750 000 | 2.82 | 61 | 381.0 | 25.38 | 1052 | 60.3 | 0.0757 |
| Petunia | 750 000 | 3.62 | 37 | 380.8 | 25.34 | 1050 | 58.6 | 0.0757 |
| Lilac | 795 000 | 2.90 | 61 | 402.9 | 26.1 | 1113 | 63.8 | 0.0716 |
| Arbutus | 795 000 | 3.72 | 37 | 402.1 | 26.04 | 1109 | 61.8 | 0.0717 |
| Snapdragon | 900 000 | 3.09 | 61 | 457.4 | 27.81 | 1263 | 70.8 | 0.0630 |
| Cockscomb | 900 000 | 3.96 | 37 | 455.7 | 27.72 | 1257 | 68.4 | 0.0633 |
| Goldenrod | 954 000 | 3.18 | 61 | 484.5 | 28.62 | 1338 | 75.0 | 0.0595 |
| Magnolia | 954 000 | 4.08 | 37 | 483.7 | 28.56 | 1334 | 72.6 | 0.0596 |
| Camellia | 1 000 000 | 3.25 | 61 | 506.0 | 29.25 | 1398 | 78.3 | 0.0570 |
| Hawkweed | 1 000 000 | 4.18 | 37 | 507.7 | 29.26 | 1400 | 76.2 | 0.0568 |
| Larkspur | 1 033 500 | 3.31 | 61 | 524.9 | 29.79 | 1450 | 81.3 | 0.0549 |
| Bluebell | 1 033 500 | 4.25 | 37 | 524.9 | 29.75 | 1448 | 78.8 | 0.0549 |
| Marigold | 1 113 000 | 3.43 | 61 | 563.6 | 30.87 | 1557 | 87.3 | 0.0511 |
| Hawthorn | 1 192 500 | 3.55 | 61 | 603.8 | 31.95 | 1668 | 93.5 | 0.0477 |
| Narcissus | 1 272 000 | 3.67 | 61 | 645.3 | 33.03 | 1782 | 98.1 | 0.0447 |
| Columbine | 1 351 000 | 3.78 | 61 | 684.5 | 34.02 | 1891 | 104.0 | 0.0421 |
| Carnation | 1 431 000 | 3.89 | 61 | 725.0 | 35.01 | 2002 | 108.0 | 0.0398 |
| Gladiolus | 1 510 500 | 4.00 | 61 | 766.6 | 36 | 2117 | 114.0 | 0.0376 |
| Coreopsis | 1 590 000 | 4.10 | 61 | 805.4 | 36.9 | 2224 | 120.0 | 0.0358 |
| Jessamine | 1 750 000 | 4.30 | 61 | 885.8 | 38.7 | 2447 | 132.0 | 0.0325 |
| Cowslip | 2 000 000 | 3.77 | 91 | 1015.8 | 41.47 | 2807 | 153.0 | 0.0284 |
| Sagebrush | 2 250 000 | 3.99 | 91 | 1137.8 | 43.89 | 3144 | 167.0 | 0.0253 |
| Lupine | 2 500 000 | 4.21 | 91 | 1266.8 | 46.31 | 3501 | 186.0 | 0.0228 |
| Bitterroot | 2 750 000 | 4.42 | 91 | 1396.3 | 48.62 | 3859 | 205.0 | 0.0206 |
| Trillium | 3 000 000 | 3.90 | 127 | 1517.1 | 50.7 | 4210 | 223.0 | 0.0190 |
| Bluebonnet | 3 500 000 | 4.22 | 127 | 1776.3 | 54.86 | 4929 | 261.0 | 0.0162 |
Frequently Asked Questions (FAQ)
What do the code words like "Peachbell", "Rose", and "Iris" mean?
These are standard industry code words (originally designated by the Association of American Railroads and ASTM) used to simplify the specification and ordering of electrical conductors. Each code word corresponds to a unique set of physical and electrical properties, such as size, stranding, and resistance, preventing errors during procurement.
What is "cmil" and how does it relate to AWG?
"cmil" stands for circular mil, which is a unit of area equal to the area of a circle with a diameter of one mil (1/1000 of an inch). It is used for sizing large conductors where American Wire Gauge (AWG) numbers become too small. For reference, 250,000 cmil is written as 250 kcmil or 250 MCM.
Why does stranding structure vary (e.g., 7, 19, 37, 61, 91, 127)?
The number of strands determines the flexibility and physical performance of the conductor. As the cross-sectional area increases, more strands are required to keep the cable flexible enough for installation and to reduce mechanical fatigue under wind and ice loading.
Why is the maximum D.C. resistance specified at exactly 20℃?
Electrical resistance in metals changes with temperature (resistance increases as temperature rises). Specifying D.C. resistance at a standardized temperature of 20℃ (68°F) provides a consistent baseline for engineering calculations, quality control, and comparison across different conductor models.
What is the difference between sectional area and conductor diameter?
Sectional area (measured in mm² or cmil) refers to the total cross-sectional area of the metal itself, which directly dictates the current-carrying capacity (ampacity). Conductor diameter (measured in mm) refers to the overall outer diameter of the stranded cable bundle, which is critical for selecting matching installation hardware, tension clamps, and conduits.