ACSR Steel Wire Core Conductor - IEC 61089 Standard China Suppliers & Factory Supply

,

Execution Standard: Our ACSR (Aluminum Conductor Steel Reinforced) products adhere to the IEC 61089 standard, ensuring high quality and reliability for your electrical needs.

,

Material: Manufactured in China, our ACSR features galvanized steel wire and high-grade A1 aluminum, making it a durable choice for various applications. As a leading supplier and factory, we guarantee competitive pricing and excellent customer service.

,
    container

    heading-type-1

    div容器

    High Tensile Strength

    Steel reinforced core provides exceptional mechanical strength to handle long spans and heavy loads.

    Optimal Conductivity

    Outer layers of high-grade aluminum offer excellent electrical performance and transmission efficiency.

    Corrosion Protection

    Galvanized steel wire cores ensure long-term durability and resistance against environmental wear.

    Aluminum Conductor Steel Reinforced (ACSR) Specifications
    Product Structure Sectional Area Diameter of Conductor Nominal Breaking Load Linear Mass Maximum Resistance at 20℃
    Code Name Aluminium Wire Diameter & Stranding Galvanized Steel Wire Diameter & Stranding Aluminium Galvanized Steel Aluminium & Steel
    mm No. mm No. mm² mm² Total (mm²) mm kN kg/km Ω/km
    16 1.84 6 1.84 1 16.0 2.7 18.6 5.52 6.08 64.6 1.7934
    25 2.3 6 2.3 1 24.9 4.2 29.1 6.91 9.13 100.9 1.1478
    40 2.91 6 2.91 1 39.9 6.7 46.6 8.74 14.4 161.5 0.7174
    63 3.66 6 3.66 1 63.1 10.5 73.6 11 21.63 254.4 0.4555
    100 4.61 6 4.61 1 100.1 16.7 116.8 13.8 34.33 403.8 0.2869
    125 2.97 18 2.97 1 124.7 6.9 131.6 14.9 29.17 397.9 0.2304
    125 2.47 26 1.92 7 124.6 20.3 144.8 15.7 45.69 503.9 0.2310
    160 3.36 18 3.36 1 159.6 8.9 168.5 16.8 36.18 509.3 0.1800
    160 2.80 26 2.18 7 160.1 26.1 186.2 17.7 57.69 644.9 0.1805
    200 3.76 18 3.76 1 199.9 11.1 211.0 18.8 42.22 636.7 0.1440
    200 3.13 26 2.43 7 200.1 32.5 232.5 19.8 70.13 806.2 0.1444
    250 3.80 22 2.11 7 249.5 24.5 274.0 21.6 68.72 880.6 0.1154
    250 3.50 26 2.72 7 250.1 40.7 290.8 22.2 87.67 1007.7 0.1155
    315 2.99 45 1.99 7 316.0 21.8 337.7 23.9 79.03 1039.6 0.0917
    315 3.93 26 3.05 7 315.4 51.1 366.5 24.9 106.83 1269.7 0.0917
    400 3.36 45 2.24 7 399.0 27.6 426.6 26.9 98.36 1320.1 0.0722
    400 3.07 54 3.07 7 399.7 51.8 451.5 27.6 123.04 1510.3 0.0723
    450 3.57 45 2.38 7 450.4 31.1 481.6 28.5 107.47 1485.2 0.0642
    450 3.26 54 3.26 7 450.7 58.4 509.2 29.3 138.42 1699.1 0.0643
    500 3.76 45 2.51 7 499.7 34.6 534.3 30.1 119.41 1650.2 0.0578
    500 3.43 54 3.43 7 499.0 64.7 563.6 30.9 153.80 1887.9 0.0578
    560 3.98 45 2.65 7 559.8 38.6 598.5 31.8 133.74 1848.2 0.0516
    560 3.63 54 2.18 19 558.9 70.9 629.8 32.7 172.59 2103.4 0.0516
    630 4.22 45 2.81 7 629.4 43.4 672.8 33.8 150.45 2079.2 0.0459
    630 3.85 54 2.31 19 628.6 79.6 708.3 34.7 191.77 2366.3 0.0459
    710 4.48 45 2.99 7 709.3 49.2 758.5 35.9 169.56 2343.2 0.0407
    710 4.09 54 2.45 19 709.5 89.6 799.0 36.8 216.12 2666.8 0.0407
    800 3.76 72 2.51 7 799.5 34.6 834.1 37.6 167.41 2480.2 0.0361
    800 3.48 84 3.48 7 799.0 66.6 865.5 38.3 205.33 2732.7 0.0362
    800 4.34 54 2.61 19 798.8 101.7 900.5 39.1 243.52 3004.9 0.0362
    900 3.99 72 2.66 7 900.3 38.9 939.2 39.9 188.33 2790.2 0.0321
    900 3.69 84 3.69 7 898.3 74.9 973.2 40.6 226.50 3074.2 0.0322
    1000 4.21 72 2.80 7 1002.3 43.1 1045.4 42.1 209.26 3100.3 0.0289
    1120 4.45 72 1.78 19 1119.8 47.3 1167.1 44.5 234.53 3464.9 0.0258
    1120 4.12 84 2.47 19 1119.9 91.0 1210.9 45.3 283.17 3811.5 0.0258
    1250 4.35 84 2.61 19 1248.4 101.7 1350.0 47.9 316.04 4253.9 0.0232
    1250 4.70 72 1.88 19 1249.2 52.7 1301.9 47 261.75 3867.1 0.0231
    Note: The outermost layer is twisted to the right (Z).
    Frequently Asked Questions (FAQ)

    What is ACSR (Aluminum Conductor Steel Reinforced)?

    ACSR is a high-capacity, high-strength stranded conductor typically used in overhead power lines. It consists of solid or stranded steel core wires surrounded by outer strands of high-purity aluminum.

    What does "outermost layer twisted to the right (Z)" mean?

    This specifies the lay direction of the outermost aluminum wires. A right-hand lay (Z-lay) is standard for outer layers, ensuring consistent mechanical performance and compatibility during installation and jointing.

    Why is galvanized steel used in the core?

    The steel core is galvanized (zinc-coated) to protect it from corrosion, extending the overall service life of the conductor in harsh outdoor environments.

    What are the main advantages of ACSR over AAC (All Aluminum Conductor)?

    Due to the steel core, ACSR has significantly higher tensile strength and lower sag than AAC, making it suitable for long-span transmission lines and overhead installations under heavy wind and ice load conditions.

    How do I select the right ACSR conductor size?

    Proper selection depends on your project requirements, including current carrying capacity (amperage), mechanical span length, wind/ice loading conditions, and target electrical resistance. Refer to our specification table for detailed structural and electrical values.