Leave Your Message

AACSR Steel Core Aluminum Alloy Conductor - High Voltage Cable from China Suppliers and Factory

,

Execution standard: IEC 61089

,

Material: AACSR utilizes galvanized steel wire and 6201 aluminum alloy.

,

ACSR (Aluminum Conductor Steel Reinforced) is a trusted solution for power transmission, featuring a durable steel core that provides exceptional tensile strength. The outer layer is composed of precision-engineered aluminum wires, ensuring optimal electrical conductivity. Designed to withstand corrosion, temperature fluctuations, and mechanical stress, ACSR is the preferred choice for reliable high-voltage power distribution across various landscapes. As a leading manufacturer and supplier in China, our factory guarantees top-quality ACSR conductors that meet your energy needs effectively.

,
    container

    heading-type-1

    div容器

    Nominal Area Sectional Area Wire Diameter & Stranding Diameter of Conductor Linear Mass Rated Strength Max.D.C. Resistance at 20℃
    Aluminum alloy Steel Total Aluminum alloy Steel
    mm² mm² mm² mm² mm No mm No mm kg/km kN Ω/km
    26 18.4 3.07 21.5 1.98 6 1.98 1 5.93 74.8 9.02 1.7934
    25 28.8 4.80 33.6 2.47 6 2.47 1 7.41 116.3 13.96 1.1478
    40 46.0 7.67 53.7 3.13 6 3.13 1 9.38 186.8 22.02 0.7174
    63 72.5 12.1 84.6 3.92 6 3.92 1 11.8 293.0 34.68 0.4555
    100 115 6.39 121 2.85 18 2.85 1 14.3 366.0 41.24 0.2880
    125 144 7.99 152 3.19 18 3.19 1 16.0 458.6 51.23 0.2304
    125 144 23.4 167 2.65 26 2.06 7 16.8 579.4 69.86 0.2310
    160 184 10.2 194 3.61 18 3.61 1 18.0 587.3 65.58 0.1800
    160 184 30.0 214 3.00 26 2.34 7 19.0 743.0 88.52 0.1805
    200 230 12.8 243 4.04 18 4.04 1 20.2 735.6 81.97 0.1440
    200 230 37.5 268 3.36 26 2.61 7 21.3 931.0 110.64 0.1444
    250 288 28.3 316 4.08 22 2.27 7 23.1 1016.6 117.09 0.1154
    250 288 46.9 335 3.75 26 2.92 7 23.8 1161.5 138.31 0.1155
    315 383 25.1 408 3.20 45 2.14 7 25.8 1198.0 136.28 0.0917
    315 383 59.0 442 4.21 26 3.28 7 26.7 1464.4 171.90 0.0917
    400 460 31.8 492 3.61 45 2.41 7 28.9 1523.8 172.10 0.0722
    400 460 59.7 520 3.29 54 3.29 7 29.7 1736.9 201.46 0.0723
    450 518 35.8 554 3.83 45 2.55 7 30.6 1713.7 193.61 0.0642
    450 518 67.1 585 3.49 54 3.49 7 31.5 1954.5 226.64 0.0643
    500 575 39.8 615 4.04 45 2.69 7 32.3 1906.8 215.12 0.0578
    500 575 74.6 650 3.68 54 3.68 7 33.2 2173.1 251.82 0.0578
    560 645 44.6 689 4.27 45 2.85 7 34.2 2131.8 240.93 0.0516
    560 645 81.6 726 3.90 54 2.34 19 35.1 2425.7 283.21 0.0516
    630 725 31.3 756 3.58 72 2.39 7 35.8 2250.4 249.62 0.0459
    630 725 91.8 817 4.13 54 2.48 19 37.2 2721.4 318.61 0.0459
    710 817 35.3 852 3.80 72 2.53 7 38.0 2534.0 281.32 0.0407
    710 817 104 921 4.39 54 2.63 19 39.5 3071.0 359.98 0.0407
    800 921 39.8 961 4.04 72 2.69 7 40.4 2864.2 316.98 0.0361
    800 921 76.7 997 3.74 84 3.74 7 41.1 3156.3 356.03 0.0362
    900 1036 44.8 1081 4.28 72 2.85 7 42.8 3214.7 356.6 0.0321
    900 1036 86.3 1122 3.96 84 3.96 7 43.6 3538.6 400.53 0.0322
    1000 1151 93.7 1245 4.18 84 2.51 19 45.9 3926.6 446.37 0.0289
    1120 1289 105 1394 4.42 84 2.65 19 48.6 4387.8 499.93 0.0258
    Frequently Asked Questions (FAQ)
    What is the difference between Nominal Area and Total Sectional Area?
    Nominal Area is a simplified standard designator used for naming and identifying the conductor size. The Total Sectional Area is the precise mathematical sum of the cross-sectional areas of both the aluminum alloy strands and the reinforcing steel strands.
    How does the steel core composition affect the Rated Strength of the conductor?
    The steel core acts as the primary load-bearing element. Higher ratios of steel sectional area to aluminum alloy sectional area significantly increase the Rated Strength (measured in kN), making the conductor suitable for longer spans and high-tension installations.
    Why is the Max D.C. Resistance specified at exactly 20℃?
    Electrical resistance changes with temperature. 20℃ is the standard reference temperature used globally in electrical engineering to allow consistent, standardized performance comparison between different conductor designs and materials.
    What is the significance of the stranding configuration (e.g., 54 Al / 7 Steel)?
    The stranding configuration determines the flexibility, overall diameter, and mechanical behavior of the conductor. More strands generally offer better flexibility and resistance to fatigue caused by vibration, while fewer strands might offer a smaller overall diameter.
    How does Linear Mass relate to shipping and installation?
    Linear Mass (kg/km) indicates the weight of the cable per unit length. This value is critical for calculating logistics costs, reel capacities, sag tensions, and structural tower loading limits during overhead transmission line design.

    Leave Your Message

    AI Helps Write