Leave Your Message

AACSR DIN 48206 Steel Core Aluminum Alloy Conductor - Quality China Suppliers & Factory for Power Transmission

,

Execution Standard: DIN 48206

,

Material: The AACSR conductor is constructed from high-quality galvanized steel wire and 6201 aluminum alloy.

,

Aluminum Conductor Steel Reinforced (AACSR) is a widely used solution in transmission lines, manufactured by trusted China suppliers and factories. The robust steel core offers exceptional support while the aluminum alloy enhances conductivity efficiency. This combination ensures excellent weather resistance and mechanical properties, allowing for the safe and efficient transmission of high-voltage power. Choose our AACSR products for reliable performance and durability in all your power transmission needs.

,
    container

    heading-type-1

    div容器

    Code Name Old Code Name Sectional Area Wire Diameter & Stranding Diameter of Conductor Linear Mass Rated Strength Max. D.C. Resistance at 20℃
    Aluminum alloy Steel Total Aluminum alloy Steel
    mm² mm² mm² mm No mm No mm kg/km kN Ω/km
    15-AL 3/3-ST1A 16/2.5 15.3 2.5 17.8 1.80 6 1.80 1 5.4 61.6 7.48 2.18
    24-AL 3/4-ST1A 25/4 23.9 4.0 27.8 2.25 6 2.25 1 6.8 96.3 11.71 1.3952
    34-AL 3/6-ST1A 35/6 34.4 5.7 40.1 2.70 6 2.70 1 8.1 138.7 16.85 0.9689
    44-AL 3/32-ST1A 44/32 44.0 31.7 75.6 2.00 14 2.40 7 11.2 369.3 50.27 0.7625
    48-AL 3/8-ST1A 50/8 48.3 8.0 56.3 3.20 6 3.20 1 9.6 194.8 23.66 0.6898
    51-AL 3/30-ST1A 50/30 51.2 29.8 81.0 2.33 12 2.33 7 11.7 374.7 50.24 0.6547
    70-AL 3/11-ST1A 70/12 69.9 11.4 81.3 1.85 26 1.44 7 11.7 282.2 33.99 0.4791
    94-AL 3/15-ST1A 95/15 94.4 15.3 109.7 2.15 26 1.67 7 13.6 380.6 45.82 0.3547
    97-AL 3/56-ST1A 95/55 96.5 56.3 152.8 3.20 12 3.20 7 16.0 706.8 94.75 0.3471
    106-AL3/76-ST1A 105/75 105.7 75.5 181.2 3.10 14 2.25 19 17.5 885.3 120.14 0.3174
    122-AL3/20-ST1A 120/20 121.6 19.8 141.4 2.44 26 1.90 7 15.5 491 59.14 0.2754
    122-AL 3/71-ST1A 120/70 122.1 71.3 193.4 3.60 12 3.60 7 18.0 894.5 119.12 0.2742
    128-AL 3/30-ST1A 125/30 127.9 29.8 157.8 2.33 30 2.33 7 16.3 587 72.8 0.2621
    149-AL 3/24-ST1A 150/25 148.9 24.2 173.1 2.70 26 2.10 7 17.1 600.8 72.36 0.2249
    172-AL 3/40-ST1A 170/40 171.8 40.1 211.8 2.70 30 2.70 7 18.9 788.2 97.75 0.1952
    184-AL 3/30-ST1A 185/30 183.8 29.8 213.6 3.00 26 2.33 7 19.0 741 89.22 0.1822
    209-AL 3/34-ST1A 210/35 209.1 34.1 243.2 3.20 26 2.49 7 20.3 844.1 101.67 0.1601
    212-AL 3/49-ST1A 210/50 212.1 49.5 261.5 3.00 30 3.00 7 21.0 973.1 120.68 0.1581
    231-AL 3/30-ST1A 230/30 230.9 29.8 260.8 3.50 24 2.33 7 21.0 870.9 103.08 0.1449
    243-AL 3/39-ST1A 240/40 243.1 39.5 282.5 3.45 26 2.68 7 21.8 980.1 118.02 0.1378
    264-AL3/34-ST1A 265/35 263.7 34.1 297.7 3.74 24 2.49 7 22.4 994.4 117.71 0.1269
    304-AL 3/49-ST1A 300/50 304.3 49.5 353.7 3.86 26 3.00 7 24.5 1227.3 147.79 0.1101
    305-AL3/39-ST1A 305/40 304.6 39.5 344.1 2.68 54 2.68 7 24.1 1151.2 136.12 0.1101
    339-AL 3/30-ST1A 340/30 339.3 29.8 369.1 3.00 48 2.33 7 25.0 1171.2 134.94 0.0988
    382-AL 3/49-ST1A 380/50 381.7 49.5 431.2 3.00 54 3.00 7 27.0 1442.5 170.56 0.0879
    386-AL 3/34-ST1A 385/35 386.0 34.1 420.1 3.20 48 2.49 7 26.7 1333.6 153.69 0.0868
    434-AL 3/56-ST1A 435/55 434.3 56.3 490.6 3.20 54 3.20 7 28.8 1641.3 194.06 0.0772
    449-AL 3/39-ST1A 450/40 448.7 39.5 488.2 3.45 48 2.68 7 28.7 1549.1 178.48 0.0747
    490-AL 3/64-ST1A 490/65 490.3 63.6 553.8 3.40 54 3.40 7 30.6 1852.9 219.07 0.0684
    550-AL 3/71-ST1A 550/70 549.7 71.3 620.9 3.60 54 3.60 7 32.4 1851.4 245.6 0.061
    562-AL3/49-ST1A 560/50 561.7 49.5 611.2 3.86 48 3.00 7 32.2 1939.5 223.48 0.0597
    679-AL 3/86-ST1A 680/85 678.6 86.0 764.5 4.00 54 2.40 19 36.0 2547.6 300.84 0.0494
    Frequently Asked Questions (FAQ)
    1. What does the Code Name (e.g., "15-AL 3/3-ST1A") represent?
    The code name indicates the specific structure of the conductor. "AL" refers to the Aluminum alloy section, "ST" represents the Steel core section, and the numbers indicate their respective nominal cross-sectional areas and material grades (e.g., ST1A grade steel core).
    2. How do I transition from Old Code Names to New Code Names?
    You can easily cross-reference the specifications using our table. For instance, the old code name "16/2.5" directly corresponds to the new standard designation "15-AL 3/3-ST1A", sharing similar physical and electrical properties.
    3. Why is Max. D.C. Resistance at 20℃ critical?
    Max. D.C. Resistance at 20℃ (measured in Ohms/km) determines the electrical efficiency of the conductor. Lower resistance values mean less power loss during transmission, which is crucial for high-efficiency grid layouts.
    4. What is the relation between Rated Strength and the steel core?
    The steel core (ST1A) provides the primary mechanical tensile strength (Rated Strength in kN). As the sectional area of the steel core increases relative to the aluminum alloy, the overall rated strength of the conductor increases significantly to support long-span installations.
    5. Are these conductors suitable for high-voltage transmission lines?
    Yes, these Aluminum Alloy Conductor Steel Reinforced (AACSR/ACSR) specifications are specifically designed for overhead electrical transmission and distribution lines, offering an optimized balance between conductivity, weight, and mechanical strength.

    Leave Your Message