Leave Your Message

AACSR DIN 48206 Steel Core Aluminum Alloy Conductor - High-Quality China Suppliers & Factory Solutions

Execution Standard: DIN 48206

Material: AACSR is made from galvanized steel wire and 6201 aluminum alloy.

The Aluminum Conductor Steel Reinforced (AACSR) is a widely used conductor for transmission lines. The robust steel core offers exceptional support, while the aluminum alloy layer enhances conductivity efficiency. Known for its excellent weather resistance and mechanical properties, AACSR ensures the safe and efficient transmission of high-voltage power. As a leading China supplier, our factory specializes in producing high-quality AACSR conductors to meet the demands of modern power distribution systems.

    container

    heading-type-1

    div容器

    Technical Specifications & Structural Parameters
    Code Name Old Code Name Sectional Area Wire Diameter & Stranding Diameter of Conductor Linear Mass Rated Strength Max. D.C. Resistance at 20℃
    Aluminum alloy Steel Total Aluminum alloy Steel
    mm² mm² mm² mm No mm No mm kg/km kN Ohms/km
    15-AL 3/3-ST1A 16/2.5 15.3 2.5 17.8 1.80 6 1.80 1 5.4 61.6 7.48 2.18
    24-AL 3/4-ST1A 25/4 23.9 4.0 27.8 2.25 6 2.25 1 6.8 96.3 11.71 1.3952
    34-AL 3/6-ST1A 35/6 34.4 5.7 40.1 2.70 6 2.70 1 8.1 138.7 16.85 0.9689
    44-AL 3/32-ST1A 44/32 44.0 31.7 75.6 2.00 14 2.40 7 11.2 369.3 50.27 0.7625
    48-AL 3/8-ST1A 50/8 48.3 8.0 56.3 3.20 6 3.20 1 9.6 194.8 23.66 0.6898
    51-AL 3/30-ST1A 50/30 51.2 29.8 81.0 2.33 12 2.33 7 11.7 374.7 50.24 0.6547
    70-AL 3/11-ST1A 70/12 69.9 11.4 81.3 1.85 26 1.44 7 11.7 282.2 33.99 0.4791
    94-AL 3/15-ST1A 95/15 94.4 15.3 109.7 2.15 26 1.67 7 13.6 380.6 45.82 0.3547
    97-AL 3/56-ST1A 95/55 96.5 56.3 152.8 3.20 12 3.20 7 16.0 706.8 94.75 0.3471
    106-AL3/76-ST1A 105/75 105.7 75.5 181.2 3.10 14 2.25 19 17.5 885.3 120.14 0.3174
    122-AL3/20-ST1A 120/20 121.6 19.8 141.4 2.44 26 1.90 7 15.5 491 59.14 0.2754
    122-AL 3/71-ST1A 120/70 122.1 71.3 193.4 3.60 12 3.60 7 18.0 894.5 119.12 0.2742
    128-AL 3/30-ST1A 125/30 127.9 29.8 157.8 2.33 30 2.33 7 16.3 587 72.8 0.2621
    149-AL 3/24-ST1A 150/25 148.9 24.2 173.1 2.70 26 2.10 7 17.1 600.8 72.36 0.2249
    172-AL 3/40-ST1A 170/40 171.8 40.1 211.8 2.70 30 2.70 7 18.9 788.2 97.75 0.1952
    184-AL 3/30-ST1A 185/30 183.8 29.8 213.6 3.00 26 2.33 7 19.0 741 89.22 0.1822
    209-AL 3/34-ST1A 210/35 209.1 34.1 243.2 3.20 26 2.49 7 20.3 844.1 101.67 0.1601
    212-AL 3/49-ST1A 210/50 212.1 49.5 261.5 3.00 30 3.00 7 21.0 973.1 120.68 0.1581
    231-AL 3/30-ST1A 230/30 230.9 29.8 260.8 3.50 24 2.33 7 21.0 870.9 103.08 0.1449
    243-AL 3/39-ST1A 240/40 243.1 39.5 282.5 3.45 26 2.68 7 21.8 980.1 118.02 0.1378
    264-AL3/34-ST1A 265/35 263.7 34.1 297.7 3.74 24 2.49 7 22.4 994.4 117.71 0.1269
    304-AL 3/49-ST1A 300/50 304.3 49.5 353.7 3.86 26 3.00 7 24.5 1227.3 147.79 0.1101
    305-AL3/39-ST1A 305/40 304.6 39.5 344.1 2.68 54 2.68 7 24.1 1151.2 136.12 0.1101
    339-AL 3/30-ST1A 340/30 339.3 29.8 369.1 3.00 48 2.33 7 25.0 1171.2 134.94 0.0988
    382-AL 3/49-ST1A 380/50 381.7 49.5 431.2 3.00 54 3.00 7 27.0 1442.5 170.56 0.0879
    386-AL 3/34-ST1A 385/35 386.0 34.1 420.1 3.20 48 2.49 7 26.7 1333.6 153.69 0.0868
    434-AL 3/56-ST1A 435/55 434.3 56.3 490.6 3.20 54 3.20 7 28.8 1641.3 194.06 0.0772
    449-AL 3/39-ST1A 450/40 448.7 39.5 488.2 3.45 48 2.68 7 28.7 1549.1 178.48 0.0747
    490-AL 3/64-ST1A 490/65 490.3 63.6 553.8 3.40 54 3.40 7 30.6 1852.9 219.07 0.0684
    550-AL 3/71-ST1A 550/70 549.7 71.3 620.9 3.60 54 3.60 7 32.4 1851.4 245.6 0.061
    562-AL3/49-ST1A 560/50 561.7 49.5 611.2 3.86 48 3.00 7 32.2 1939.5 223.48 0.0597
    679-AL 3/86-ST1A 680/85 678.6 86.0 764.5 4.00 54 2.40 19 36.0 2547.6 300.84 0.0494
    Frequently Asked Questions
    What does the AL 3/ST1A designation indicate?

    "AL 3" designates the heat-treated aluminum-magnesium-silicon alloy strands that provide electrical conductivity, while "ST1A" specifies the core made of standard galvanized steel wire (Class A zinc coating) providing primary mechanical tensile strength.

    How does an AACSR conductor differ from standard ACSR?

    AACSR uses high-strength aluminum alloy (AL 3) instead of electrolytic refined aluminum (AL 1). This delivers significantly higher ultimate tensile strength and sag resistance, making it ideal for longer spans and extreme weather conditions.

    Why is maximum D.C. resistance specified at 20°C?

    The 20°C standard serves as the universal thermal baseline defined in IEC and EN electrical standards, ensuring standardized quality verification and allowing precise temperature-correction calculations for overhead line ampacity.

    What environmental conditions favor the installation of AL 3/ST1A conductors?

    These conductors excel in high-wind regions, heavy icing zones, valley and river crossings, and mountainous overhead routes where superior tensile loads, vibration resistance, and span lengths are mandatory.

    How are the total sectional area and linear mass correlated?

    Total sectional area represents the sum of the aluminum alloy and steel cross-sections. The proportion of denser galvanized steel directly drives total linear mass (kg/km) and dictates tower payload calculations and tension profiles.