Leave Your Message

0.6/1kV ABC Cable AS 3560.1 - China Suppliers & Factory with 2 to 4-Core Construction and XLPE Insulation

,

Standards: AS 3560.1

,

CONSTRUCTION
Ⅰ、Available in 2, 3, or 4-core configurations;
Ⅱ、Phase and neutral conductors are of equal size and type for consistent performance;
Ⅲ、Conductor sizes range from 16 mm² to a maximum of 150 mm²;

,

Phase Conductor
Featuring a circular stranded, rounded, and compacted aluminum conductor, ensuring optimal conductivity.

,

Neutral (Messenger) Conductor
Equipped with a circular stranded, rounded, and compacted aluminum conductor for reliable performance.

,

Insulation
Black colored cross-linked polyethylene (XLPE) insulation provides enhanced durability and resistance.

,

As a leading supplier and factory in China, we pride ourselves on delivering high-quality construction materials that meet international standards. Our products are designed to ensure safety and efficiency in various applications, making us a trusted choice for customers worldwide.

,
    container

    heading-type-1

    div容器

    Type of conductor or core Nominal cross- sectional area mm2(Core) Number of wires min. Resistance at 20 °C Ω/km Max. Dia.of Conductor Breaking force (N) Thickness of dielectric mm Outside diameter mm
    MIN MAX MIN MAX
    Phase or neutral (aluminium) 16(2/4) 6 1.91 4.5 4.8 2200 1.3 7.1 7.9
    25(2/3/4) 6 1.20 5.8 6.1 3500 1.3 8.4 9.2
    35(2/3/4) 6 0.868 6.8 7.2 4900 1.3 9.4 10.3
    50(2/3/4) 6 0.641 8.0 8.4 7000 1.5 11 11.9
    70(4) 12 0.443 9.6 10.1 9800 1.5 12.6 13.6
    95(2/4) 15 0.320 11.3 11.9 13300 1.7 14.7 15.9
    120(4) 15 0.253 12.8 13.5 16800 1.7 16.2 17.5
    150(4) 15 0.206 14.1 14.9 21000 1.7 17.5 18.9

    Frequently Asked Questions

    What is the maximum resistance for a 16 mm² aluminium conductor at 20 °C?
    The maximum electrical resistance for a 16 mm² nominal cross-sectional area aluminium conductor at 20 °C is 1.91 Ω/km.
    How does the cross-sectional area affect the breaking force of the conductor?
    As the nominal cross-sectional area increases, the breaking force also increases. For example, a 16 mm² conductor has a breaking force of 2200 N, whereas a larger 150 mm² conductor has a breaking force of 21000 N.
    What is the minimum number of wires required for a 70 mm² conductor?
    A phase or neutral aluminium conductor with a nominal cross-sectional area of 70 mm² requires a minimum of 12 wires.
    What is the range of the outside diameter for a 95 mm² conductor?
    For a 95 mm² conductor, the outside diameter ranges from a minimum of 14.7 mm to a maximum of 15.9 mm.
    How does dielectric thickness scale with the conductor size?
    The thickness of the dielectric starts at 1.3 mm for sizes 16 mm² to 35 mm², increases to 1.5 mm for 50 mm² and 70 mm² sizes, and reaches a maximum of 1.7 mm for conductor sizes of 95 mm² up to 150 mm².

    Leave Your Message